21
6.
Raise and lower the lift at the beginning of each shift, without a vehicle on, to
verify the lift is leveled and operating properly. Perform hydraulic leveling
procedure when the lift is out of level.
WEEKLY:
1. Check and adjust hydraulic level
EVERY TWO MONTHS:
1.
Clean and re-grease slide block channels inside of both columns
2.
Grease arm pins
3.
Check and lubricate safety dogs and safety cable adjustment
4.
Check arm restraints and lubricate
5.
Dismantle and clean inner arms
6.
Check anchor bolts and re-torque if required
7.
Check bolts on the carriage stops for tightness. Note: The carriage stop on the
slave side tower should have the thicker side facing downwards, and on the power
side facing upwards. Refer to
Figure 18
.
TOP
POWER SIDE SLAVE SIDE
TOWER
TOWER
Figure 18 – Carriage Stops
EVERY YEAR:
1.
Inspect lift as per Automotive Lift Operation, Inspection and Maintenance
(ALOIM)
EVERY TWO YEARS:
1.
Change hydraulic fluid
LUBRICATION:
Where grease is required > multi-purpose lithium grease
Where lubricating oil is required > multi-purpose SAE 30 lubricating oil
Where hydraulic oil is required > ISO 32 10W - non detergent hydraulic
oil
NOTE: If lift locks while in the fully raised position this will indicate that the