12
T
4
UP
CONTROL
MICROSWITCH
BUTTON
SHUT-OFF
(NORMALLY OPEN)
(NORMALLY CLOSED
DURING OPERATION)
M
T
1
230 VOLTS AC
SINGLE PHASE
POWER SUPPLY
Figure 8 – Electrical Diagram
5.8 HYDRAULIC SYSTEM INSTALLATION
Refer to
Figure 9
and
10
, and the Hydraulic System Parts List on page 26
Note: Save hydraulic caps and plugs for future use.
1.
Do not tighten any hydraulic fittings until all connections have been made.
2.
Remove plug from item 17. Install item 17 (page 26) to the 90° fitting on the
power pack (item 18).
3.
Install the valve block to the power side tower using items 23 & 5.
4.
On the power side cylinder, remove the cap off item 28 at the bottom rear and
install item 27.
5.
Attach item 27 to item 53 on valve block.
6.
At the bottom of the power side cylinder, remove the 1/4” cap from item 25 and
attach it to item 51 on valve block.
7.
Attach the other end of item 17 to the 90
°
fitting (item 18) on the valve block.
8.
Remove the two caps on item 39 and place it in the crossmember. Connect the slave
side end of this line to a bulkhead fitting (item 1) attached to the hydraulic line
(item 6).