14
BOC Smootharc 180 Multiprocess operating manual
Cast
Helix
Cast – Diameter of the circle
Helix – Vertical height
Cast and Helix
black residue is found on the cloth the surface of the wire is not properly
cleaned.
Cast and Helix
The cast and helix of the wire has a major influence on the feedability of
MIG/MAG wire.
If the cast is too large the wire will move in an upward direction from the
tip when welding and if too small the wire will dip down from the tip.
The result of this is excessive tip wear and increased wear in the liners.
If the helix is too large the wire will leave the tip with a corkscrew effect.
Selection of the Correct Power Source
Power sources for MIG/MAG welding is selected on a number of different
criteria, including:
1
Maximum output of the machine
2
Duty cycle
3
Output control (voltage selection, wire feed speed control)
4
Portability
The following table gives an indication of the operating amperage for
different size wires.
Wire Size
Amperage Range (A)
0.8 mm
60–180
0.9 mm
70–250
1.0 mm
90–280
1.2 mm
120–340
Selection of the Correct Polarity on the Power Source
Many power sources are fitted with an optional reverse polarity dinse
connector.
To achieve the optimum welding it is important to adhere to the
consumable manufacturer's instruction to select the polarity.
As a general rule all solid and metal cored wires are welded on electrode
positive. (Work return lead fitted to the negative connector.)
Some grades of self shielded flux cored wires (i.e. E71T-11, E71T-GS etc)
needs to be welded on electrode negative. (Work return lead fitted to
the positive connector.)
Selection of the Correct Shielding Gas
The selection of the shielding gas has a direct influence on the
appearance and quality of the weldbead.
The thickness of the material to be welded will determine the type of
shielding gas that has to be selected. As a general rule the thicker the
material (C-Mn and Alloy steels) are the higher the percentage of CO
2
in
the shielding gas mixture.
Different grades of shielding are required for materials such as stainless
steel, aluminium and copper.
The following table gives an indication of the most common shielding
gases used for Carbon Manganese and alloy steel.
Material thickness
Recommended shielding gas
1–8 mm
Argoshield Light
5–12 mm
Argoshield Universal
>12 mm
Argoshield Heavy