MAINTENANCE MANUAL SUPPLEMENT
Airplanes with Smiths 2307 Model Fuel Quantity
Indicators with TSU
EFFECTIVITY
NOT OK – Replace the FUELING POWER CONT
switch, S156, on the P15 panel. IF-
OK – Replace the QTY TEST switch, S257,
in the flight compartment. IF-
NOT OK – Replace the fueling power control relay, R11, on the E3 electrical shelf.
THERE ARE NO VALUES SHOWN ON THE REFUEL QUANTITY INDICATORS (ALL P15 INDICATORS) –
Make sure the refuel panel floodlights are on if installed. IF-
Refuel Indicators Inoperable