WD3060 - WD5090
USER MANUAL
28
ALARM ID
DISPLAY MESSAGE
MEANING AND SUGGESTED USER ACTION
ID47,
ID48,
ID49, ID50
“Pump 2, 3, 4 or 5 tube
clogged”
.The same checks as ID41, for the detergents 2, 3, 4, 5.
ID52
“Door 1 electrically open”
Door locking mechanism failure.
1. Make sure the door is closed properly before starting a cycle.
2. Do not force the door open with a cycle in progress; always
use the buttons provided on the appliance to stop a cycle and
open the door.
3. Check there is nothing between the door and the appliance’s
chamber preventing the door from closing properly.
4. Follow the
DEFAULT PROCEDURE
described above.
ID54
“Door 1
mechanically open”
Door opening detected with cycle in progress. Door interlock
microswitch malfunction.
.The same checks as for ID52.
ID56
“Doorlock 1
failure”
.The same checks as for ID52.
ID58
“Drying 1
failure”
Drying heating system failure.
.follow the
DEFAULT PROCEDURE
described above.
.Check the condition of the safety thermostat (push the second
red plunger on the upper wall of the detergent cabinet to reset
the thermostat).
ID60
“Drying 1
Safety Switch on”
Drying heating system failure.
.Check the condition of the safety thermostat (push the second
red plunger on the upper wall of the detergent cabinet to reset
the thermostat).
ID62
“Heating
Thermostat on”
Chamber Heating elements safety device intervened.
.Check the condition of the safety thermostat (push the first red
plunger on the upper wall of the detergent cabinet to reset the
thermostat).
ID67
“Cooling failed
WARNING: high Temp”
Dryer motor “cooling” malfunction. “Cooling” phase is included
at the end of the drying phase to bring the load processed and
the heating elements to a safe temperature.
.follow the
DEFAULT PROCEDURE
described above.
ID68
“Tank 1
empty”
.Check that there is detergent in the jerry can P1 or that the level
sensor is operating correctly.
ID69,
ID70,
ID71, ID72
“Tank 2, 3, 4 or 5
empty”
.Check that there is detergent in the jerry can or that the level
sensor is operating correctly.
ID73
“Archive error”
Internal memory data storage error.
.follow the
DEFAULT PROCEDURE
described above.
ID75
“Lack of
salt”
.Add salt to the softener salt tank inside the chamber, accessible
with the door open.