WD3060 - WD5090
USER MANUAL
29
ALARM ID
DISPLAY MESSAGE
MEANING AND SUGGESTED USER ACTION
ID77
“Temperature
> 45”
Intake water temperature over 45°C; prewash temperature must
be below 45°C.
.Wait for the appliance to cool before starting a new cycle.
.Check the cold water temperature
.Verify the correct setting of the water supply.
ID78
“Recovery
failed”
Microprocessor error.
Call the Technical Assistance Service if the fault persists.
ID79
“Program
not congruent”
This alarm is triggered if a program is created using the
WDTRACE software using settings not compatible for the proper
performance of the cycle.
.Reconsider the program created phase by phase
ID80
“Warm water
flowmeter failure”
Warm Water, intake control system failure.
.Check the water supply settings.
ID81
“Demi water
flowmeter failure”
Demi Water, intake control system failure.
.Check the water supply settings.
ID82
“System failure
sol 1”
Door locking mechanism failure.
1. Make sure the door is closed properly before starting a cycle.
2. Do not force the door open with a cycle in progress; always
use the buttons provided on the appliance to stop a cycle and
open the door.
3. Check there is nothing between the door and the appliance’s
chamber preventing the door from closing properly.
4. Follow the
DEFAULT PROCEDURE
described above.
Anomalia nella chiusura porta della vasca.
ID84
“Overtemperature
TA1”
Dryer temperature reading higher than target temperature.
. Follow the
DEFAULT PROCEDURE
described above.
ID91
“Archive
full”
Internal memory full.
.Memory space must be cleared to allow use of the appliance to
continue: this can be done by connecting to the appliance by
means of the RS-232 serial port and using the WDTRACE
software.
ID92
“Change
filter”
The absolute filter in the drying system has exceeded the set
number of working hours. Contact the After-Sales Service to
have the filter changed. The filter is a consumable and is not
covered by the warranty.
ID93
“Service”
The appliance has exceeded the set number of operating hours
since installation or since its last service: contact the After-Sales
Service for routine maintenance.
ID94
“Temperature
floating”
Temperature below TARGET temperature during extension
phase.
. Follow the
DEFAULT PROCEDURE
described above.