ALARMS MESSAGES
There are two different situations, depending on how serious the fault is:
warning messages
; there will be a message allowing the user to ignore the warning and proceed with the
selected cycle.
true alarm signals
. The user must press the “
RESET
” button and comply with the relative procedure in order
to overcome the situation.
By and large, an alarm indicates that the machine is operating in a faulty way and needs to be repaired by a
technician. Sometimes, however, the alarm may be caused by a temporary situation. Before calling the authorized
Technical Assistance service, you are therefore advised to make a RESET and repeat the cycle a second time. Call the
authorized Technician if the alarm persists.
When an alarm message is noticed: Refer to the table below to find out what the code means and the relevant
countermeasures.
Apply the countermeasures recommended for the specific circumstances.
DEFAULT PROCEDURE
for all the alarms:
1. Perform the
RESET
cycle.
2. If the alarm message disappears after the
RESET
cycle: normal use of the device can be
restarted.
3. If the alarm message persists after the
RESET
cycle: switch the device off and back on using the
“
On/Off
” main switch (Wait at least 10 seconds after switching off before switching back on
again).
4. If the alarm occurs when the device is restarted: retry the
RESET
.
If a cycle has been stopped during a high temperature phase, remember that the temperature must drop
below 45°C before the door can be opened.
If the alarm persists even after the RESET procedure:
1. Turn off the water supply taps.
2. Disconnect the appliance from the electricity supply.
3. Check that all the device’s connections (electricity and water) are correct and there have been no changes
from the initial installation conditions.
4. Contact the After-Sales Service.
In case of water leakage:
immediately Turn off the water supply taps and contact the After-Sales service.
Maintenance and any repairs must be carried out by authorized technical staff.
For your own safety and for the safety of the device, the user activities are limited to control activities,
external to the device, and to the activation of the RESET cycle, if requested.
ALARM ID
DISPLAY MESSAGE
MEANING AND SUGGESTED USER ACTION
ID1
“Water heating failed”
Water not heated within time allowed.
.Check the condition of the safety thermostat (push the first red
plunger on the upper wall of the detergent cabinet to reset the
thermostat).
ID2
“Temp. Probe TL1-TC”
The temperature difference between the two probes, “TL1” and
“TC”, is more than 2°C
.
follow the
DEFAULT PROCEDURE
described above.
ID4
“Overtemperature TL1”
Probe “TL1” (chamber temperature) reads a higher temperature
than the target one.
.follow the
DEFAULT PROCEDURE
described above.