15
Set at “on” for minimum rinsing temperature as set; set at “off” for rinsing regardless of boiler
temperature. If the parameter is set as “off” and hot intake water is not used, the minimum rinsing
temperature might be a few degrees lower than the setting.
If the termostop device is set “off” the rinsing is no longer monitored and the user is responsible
for ensuring that the minimum correct T° are maintained for the tank and boiler. It is particularly
important to check the intake water temperature. Also refer to the insufficient washing/drying / foam in
tank point of the “troubleshooting” section: restore T Stop ON and/or connect the appliance to a hot
water supply
6.10
Rinse aid pump (display and if required reset during maintenance)
To reset, press
for 3 seconds
.
6.11
Detergent pump
(display and if required reset during maintenance)
To reset, press
for 3 seconds
.
6.12
Energy consumption – Display and reset if required
To reset, press
for 3 seconds
.
6.13
Customisation of duration of program P4.
The duration of program
P4
can be
customised from
3 to 10 minutes
Access the programming procedure and scroll through to
“
ınF
” using the
button, then to 03:00 and press the
button to set the time required (from 3 to 10 minutes)
After a few seconds without the user pressing any buttons,
the display will return to the normal operating status and the
modifications will be saved.
Содержание PROFESSIONAL GLASSWASHER