background image

 

 

 

 

17 

filter,  possible damage to  water  intake hose or cleaning  of  rinsing 
nozzles. If the problem persists during FILL: 
- tank pressure switch has failed (continuous empty reading:  check 
whether tank safety pressure switch  is tripped) 
- leak from pipe connected to air trap  
If the problem occurs during work cycle 
-  filler  hose  bleeder  valve  fouled:  tank  empties  completely  at  end 
of a wash cycle due to siphon effect. 

Err06 

Water pump-out malfunction 

 

 

Inspect  the  filters  for  dirt  and  check  that  the  drain  hose  is  not 
blocked, bent or crushed. 
Check that the drain pump is not blocked by dirt by removing the 
insert on the sump (from inside the tank). 
If it persists, check in this order: 
- with tank empty: constant “tank full” signal:  tank pressure switch 
faulty or leak from connections of air trap connection pipe (water 
entering pipe) 
- with tank full: drain pump failure 

Err09 

Too much water in tank 

With tank full: 
see above (water pump-out malfunction) 
With tank empty: constant “tank full” signal: safety pressure switch 
faulty or leak from connections of air trap connection pipe (water 
entering pipe) 

Err23 

Boiler  does  not  heat  up  as 
expected  

The problem might occur because water is continually entering the 
tank (the causes are as for  Err5 – see above) 
If it persists, check in this order: 
- damaged boiler heating element 
- contactor failure, 
- boiler safety thermostat failure, 
- boiler temperature probe faulty or incorrectly positioned 
- motherboard relay failure, 
Important: if the boiler heating element is damaged, this might be 
due to operation with no water in the boiler - the pressure switch 
is indicating full even with the boiler empty: check and if necessary 
replace the boiler air trap and/or the relative pressure switch: the 
problem is generally preceded by “boiler overheating E28” 

Err24 

Boiler 

temperature 

probe 

malfunction 

boiler temperature probe disconnected or not working 

Err25 

Boiler 

water 

filling 

malfunction  

The boiler does not fill within the allowed time: check water intake 
tap,  dynamic  pressure  in  intake  system,  cleaning  of  water  intake 
filter, possible damage to water intake hose 
Or check in this order: 
- boiler pressure switch has failed (continuous empty reading) 
 - pipe leaking/disconnected (water entering pipe) 

Err26 

Boiler emptying malfunction 

- check that rinsing spray arm nozzles are clean 

Содержание PROFESSIONAL GLASSWASHER

Страница 1: ...PROFESSIONAL GLASSWASHER ...

Страница 2: ...p 13 6 6 Detergent dispensing setup 13 6 7 Autostart function 14 6 8 Regeneration frequency setup models with softener 14 6 9 tStP minimum rinsing temperature function 14 6 10 Rinse aid pump display and if required reset during maintenance 15 6 11 Detergent pump display and if required reset during maintenance 15 6 12 Energy consumption Display and reset if required 15 6 13 Customisation of durati...

Страница 3: ...nspection of the spray arms 26 11 3 Lengthy periods out of use 26 12 TROUBLESHOOTING 27 13 MALFUNCTIONS SHOWN ON THE DISPLAY FOR THE USER 29 SMEG thanks you for choosing one of its products Read all the instructions in this manual carefully to become familiar with the right conditions for the proper use of your glasswasher TECHNICAL INSTRUCTIONS These are intended for the qualified staff who are t...

Страница 4: ...CT WAS PURCHASED THIS MANUAL IS AN INTEGRAL PART OF THE GLASSWASHER AND MUST ALWAYS BE KEPT INTACT TOGETHER WITH THE APPLIANCE POSITIONING HOOKUP COMMISSIONING TROUBLESHOOTING AND REPLACING THE POWER CABLE MUST ALWAYS BE CARRIED OUT BY QUALIFIED STAFF THE APPLIANCE MUST BE GROUNDED AS REQUIRED BY ELECTRICAL EQUIPMENT SAFETY STANDARDS THE SYMBOL OF THE RUBBISH BIN WITH A BAR ACROSS IT ON THE PRODUC...

Страница 5: ...50 C s 90 150 240 Noise level dB A 50 Degree of protection IPX 4 5 Net weight Kg CWG 60 63 CWH 84 87 Power supply cable type HAR H07RN F Fuse A 4 SEE APPLIANCE LABEL VOLTAGE FUSE PROTECTION TANK HEATING MOTOR BOILER 1 5X3 TOTAL CONNECTION Current POWER CABLE 400V 50Hz 3 N PE 13A 0 8kW 0 7kW 5kW 5 7kW 11A 5X2 5 230V 50Hz 3 PE 25A 0 8kW 0 7kW 5kW 5 7kW 16A 5X2 5 230V 50Hz 1 N PE 2RR 25A 0 8kW 0 7kW ...

Страница 6: ...5 CAVITY DIMENSIONS FOR BUILT UNDER INSTALLATION APPLIANCE DIMENSIONS AND CONNECTION POSITIONS N B VALUE 1000 max 600 if siphon with valve is used N B VALUE max 60 heat exchanger ...

Страница 7: ... be reported to the transporter in writing The packaging components plastic bags expanded polystyrene nails etc must not be left within reach of children and pets since they are potentially dangerous All packaging materials used are environment friendly They can be kept without constituting any hazard or may be disposed of at a specialist waste disposal centre The plastic components suitable for r...

Страница 8: ...EFFECTIVE DEVICE PROVIDING BACKFLOW PREVENTION PROTECTION TO AT LEAST FLUID CATEGORY TWO SHALL BE FITTED AT THE POINT OF CONNECTION BETWEEN THE WATER SUPPLY AND THE FITTING OR APPLIANCE The dynamic water supply pressure must be between 1 and 6 bar if it is higher a pressure reducer must be installed It is essential to fit a main stop tap on the water intake deliver pipeline the tap must be accessi...

Страница 9: ...ity supply line in accordance with the relevant regulations These switches must be installed close to the glasswasher be easily accessible after installation and provide complete disconnection from the electrical mains in overvoltage class III conditions Warning The glasswasher is always powered up unless the master switch is turned off Connect the appliance to the user s earth system The terminal...

Страница 10: ... relative kit As an alternative an external dispenser can be fitted making the electrical connection by means of an H05 RN F 2x0 5 mm electrical cable which can be laid along the route shown in the TECHNICAL DATA diagram and connected as shown in the wiring diagram supplied with the glasswasher The dispenser must operate on 230V 50 Hz with maximum power absorption of 15 W Connect to the detergent ...

Страница 11: ... down for 5 7 seconds When the second beep is heard release the button and press it again to access the main PCB setup menu Rinsing temperature boiler temperature IMPORTANT Whenever the type of detergent or rinse aid is changed it is ABSOLUTELY ESSENTIAL to flush out the peristaltic pumps by placing the external intake pipes in water for a few cycles Always use only products specifically recommend...

Страница 12: ...n to start the cycle when the door is closed Set at off for cycle start after confirmation with the start button Water hardness setting OPT on models with softener only tStP on off on minimum rinsing temperature as set regardless of intake water temperature If the intake water is not hot the cycle duration might be a few seconds longer than the nominal timing off the minimum rinsing temperature mi...

Страница 13: ...r reset unless the software is reprogrammed Customisation of duration of program P4 This submenu and the relative functions can only be accessed with the aid of a password available on SmegTech and only by technical staff 6 2 Quit SET UP menu Wait more than 10 seconds without pressing any button and the appliance quits this menu automatically or press the on off button to exit Indicator lights sho...

Страница 14: ...or lights showing off green orange flashing 6 5 Rinse aid dispensing setup Modify the value of the parameter by pressing RINSE AID Delivery time s Delivery quantity c c 0 0 0 6 0 7 default value factory preset 12 1 3 18 2 0 24 2 7 30 3 3 36 4 0 42 4 7 6 6 Detergent dispensing setup Modify the value of the parameter by pressing DETERGENT Delivery time s Delivery quantity c c 0 0 0 4 1 7 8 3 3 defau...

Страница 15: ...lt tank has to be filled It is subsequently sufficient simply to fill up with regenerating salt when necessary Modify the value of the parameter by pressing Hardness dH German degrees Hardness dF French degrees Setting level Regeneration off Regeneration off H00 8 5 15 H01 11 20 H02 17 30 H03 22 5 40 H04 28 50 H05 Regeneration cycle duration 12 minutes 33 5 60 H06 With values over 60 dF an externa...

Страница 16: ...oting section restore T Stop ON and or connect the appliance to a hot water supply 6 10 Rinse aid pump display and if required reset during maintenance To reset press for 3 seconds 6 11 Detergent pump display and if required reset during maintenance To reset press for 3 seconds 6 12 Energy consumption Display and reset if required To reset press for 3 seconds 6 13 Customisation of duration of prog...

Страница 17: ...c pump fills the circuit in about 7 minutes while for the detergent it only takes 2 minutes So draw only rinse aid from the jerry cans 1 for the rinse aid and the other for the detergent for the first 5 minutes and then also take in detergent for the last 2 7 MALFUNCTIONS SHOWN ON THE DISPLAY FOR THE TECHNICIAN The glasswasher is able to identify a number of malfunctions and show them on the displ...

Страница 18: ...ap connection pipe water entering pipe Err23 Boiler does not heat up as expected The problem might occur because water is continually entering the tank the causes are as for Err5 see above If it persists check in this order damaged boiler heating element contactor failure boiler safety thermostat failure boiler temperature probe faulty or incorrectly positioned motherboard relay failure Important ...

Страница 19: ...h has failed continuous full reading pipe leaking disconnected water entering pipe connected to air trap pressure switch continues to give full reading even with boiler empty heating element operating dry Or circuit board relay failure or contactor failure 8 INSTRUCTIONS FOR THE USER 8 1 Control panel On off button Program selection button Start CONFIRM PAUSE button Total emptying button tank and ...

Страница 20: ...his glasswasher Turn on the mains water tap user Check Switch on the master switch user the word OFF appears on the display The level of detergent and rinse aid in the containers That there is regenerating salt in the relative container if fitted That the filters are in place the spray arms rotate and there are no foreign bodies in the glasswasher When topping up the tanks take care not to swap th...

Страница 21: ...ature is reached The duration of this stage may vary depending on the mains water temperature and on the single phase connection Press the button quickly to display the tank left and boiler right temperatures for a short time Load the dishes Select the program required by pressing Confirm the program start by pressing and holding it down for 1 second light L2 changes from green to orange Cycle in ...

Страница 22: ...ess and hold it down to interrupt it change the program by pressing Confirm the program start by pressing and holding it down for 1 second light L2 changes back to orange N B During heating of the water in the boiler and tank with the cycle running the tank heating element and boiler heating element symbols may appear on the display Filter presence sensor on some models only The filter is fitted w...

Страница 23: ...washer is fitted with the HTR system which requires set temperature and pressure for rinsing 10 SUPPLEMENTARY FUNCTIONS Indicator lights showing off green orange flashing To select a supplementary function when the program required is shown on the display P1 P2 P3 or P4 press the button Only one supplementary function can be selected for each program 10 1 Selecting the crys glassware function avai...

Страница 24: ...ing the sanitisation function only available in P3 Increases the program s washing and rinsing temperatures and duration Press to select the sanitisation function then to confirm the program start N B the supplementary function remains selected until the program is changed or the glasswasher is switched off by pressing the button During execution of the selected program the display alternates betw...

Страница 25: ...lasswasher off with water in the tank always pump out first TOTAL PUMP OUT AT THE END OF THE DAY RESIN REGENERATION for models with water softener From time to time on models with water softener before the total pump out at the end of the day the user will automatically be reminded to carry out the resin regeneration cycle required after a number of washes which depends on the hardness of the wate...

Страница 26: ...ular scheduled maintenance is required users are advised to have the glasswasher checked by a specialist technician twice a year N B the manufacturer accepts no liability for wilful damage or damage deriving from carelessness neglect failure to comply with instructions regulations and standards or incorrect connections 11 1 Daily cleaning The glasswasher has IPX4 protection but the use of direct w...

Страница 27: ...utine inspection of the spray arms Remove the washing and rinsing top and bottom spray arms by unscrewing the central screw remove the rinsing spray arms 3 and remove the screws 2 as shown Do not unscrew the nozzles Clean the holes and nozzles under a jet of clean running water do not use tools which might cause damage Reassemble the spray arms with care Clean the outside of the appliance with a d...

Страница 28: ... Remove spray arms and clean them 10 2 Periodic checks Filter fouled See Cleaning the filter during the day Too little or unsuitable detergent or rinse aid Check type and quantity of detergent No or not enough detergent or rinse aid being supplied detergent or rinse aid not being taken from the relative container Pipe inside detergent and or rinse aid peristaltic pump worn or broke have it replace...

Страница 29: ... Stop ON and or connect the appliance to a hot water supply If the problem persists contact the after sales service STAINS ON GLASSES AND CUTLERY Drain hose incorrectly positioned or partially obstructed Check that the glasswasher drain hose and rain are unobstructed and the drain is not too high up see connection diagram WATER IN TANK AFTER PUMP OUT Drain hose incorrectly positioned or partially ...

Страница 30: ...eft full of water Inspect the filters for dirt and check that the drain hose is not blocked bent or crushed Check that the drain pump is not blocked by dirt proceed as described in point 10 2 Periodic checks If the problem persists contact the After Sales Service Err09 Tank water level too high Contact the After Sales Service Err23 Boiler heating malfunction does not heat up Contact the After Sale...

Страница 31: ... you with guidance about keeping your appliance functioning correctly and put you in touch with your nearest authorised Service Centre Our whole product offering can be viewed at www smegfoodservice com International customers please contact your local SMEG distributor Smeg S p A Via Leonardo da Vinci 4 42016 Guastalla Reggio Emilia Tel 39 0522 8211 Fax 39 0522 821453 email foodservice smeg it 19 ...

Отзывы: