When mounting the SMCSD10-Z on a wall, place 
it so the top is 4 to 12 inches (10 to 31cm) below 
the ceiling. 

In rooms with sloped, peaked, or gabled ceilings, 
place the SMCSD10-Z 3 feet (.9 m) down or away 
from the highest point of the ceiling. 

If mounting to suspended ceiling tile, secure the 
tile with the appropriate fastener to prevent tile 
removal. 

Smoke detectors are not to be used with alarm 
guards unless the combination has been 
evaluated and found suitable for that purpose. 

Note:

 

A smoke detector does not provide 

warnings for fires resulting from explosions, 
smoking in bed or other furniture; ignition of 
flammable liquids, vapors and gasses; and children 
playing with matches or lighters. 

Locations to Avoid 

 

Areas where normal ambient temperature 
exceeds 100° F (37.8° C). 

 

Dirty, dusty, insect infested areas. 

 

In or near areas with combustion particles 
(kitchens, garages, furnaces, hot-water 
heaters, gas space heaters). 

 

On the ceiling in rooms next to kitchens, 
where there is no transom between the 
kitchen and such rooms. 

 

Damp or humid areas, or near bathrooms 
with showers. 

 

Near fresh-air inlets or returns or very drafty 
areas. 

 

Near heating/air conditioning vents, fans, 
and fresh air intakes, which can drive smoke 
away from the smoke alarm. 

 

In dead-air spaces at the top of peaked 
ceilings or in corners where walls and ceiling 
meet. Dead air can prevent smoke from 
reaching a smoke detector. 

 

Within 10 feet (3 m) of fluorescent light 
fixtures. 

 

Not suitable for outdoor use. 

WARNING! LIMITATIONS OF SMOKE 
DECTECTORS 

The SMCSD10-Z Smoke Detector does not contain 
a built-in audio alarm. It is not intended for 
stand-alone use; it MUST be used with an 
approved Touchscreen.  

Wireless smoke detectors are very reliable, but 
may not work under all conditions. No fire alarm 
product provides total protection of life or 

property. Smoke detectors are not a substitute 
for life insurance. 
Smoke detectors require a source of power to 
work. 

This smoke detector does not operate and the 
alarm will not sound if batteries are dead or not 
installed properly. 
This SMCSD10-Z relies on the Touchscreen Alarm 
to sound an audible alarm in case of fire. The 
alarm may not be heard. A sound sleeper or 
someone who has taken drugs or alcohol may not 
awaken if Touchscreen is installed outside a 
bedroom. Closed or partially closed doors and 
distance can block sound. This product is not 
designed for the hearing impaired. 

Smoke detectors may not always activate and 
provide warning early enough. Smoke detectors 
only activate when enough smoke reaches the 
product’s smoke chamber. If a fire starts in a 
chimney, wall, roof, on the other side of closed 
doors, or on a different level of the property, 
enough smoke may not reach the product for it 
to alarm. 

Smoke detectors are a significant help in 
reducing loss, injury and even death. However, 
no matter how good a detection device is, 
nothing works perfectly under every 
circumstance and we must warn you that you 
cannot expect a smoke detector to ensure that 
you will never suffer any damage or injury.

Содержание SMCSD10-Z

Страница 1: ...Pre installation Considerations Install the SMCSD10 Z in accordance with the National Fire Protection Association s NFPA Standard 72 Chapters 2 and 8 Depending on the application you may need to reference other chapters of NFPA 72 or NFPA 101 Choosing an Installation Location When choosing an installation location consider Use of structure and type of construction Contents you want to protect and ...

Страница 2: ...t smoke from reaching a smoke detector Within 10 feet 3 m of fluorescent light fixtures Not suitable for outdoor use WARNING LIMITATIONS OF SMOKE DECTECTORS The SMCSD10 Z Smoke Detector does not contain a built in audio alarm It is not intended for stand alone use it MUST be used with an approved Touchscreen Wireless smoke detectors are very reliable but may not work under all conditions No fire a...

Страница 3: ...atteries Do not replace with batteries that were used previously D Reattach the SMCSD10 Z to the mounting base and test the system E The SMCSD10 Z ships with a dust cover for protection on construction sites with dusty environments If your product is new remove the red plastic dust cover from the SMCSD10 Z 6 Pairing with Touchscreen Each SMCSD10 Z is programmed with a unique ID when manufactured T...

Страница 4: ...SMCSD10 Z Add the SMCSD10 Z to the Touchscreen before physically mounting it in the desired location A Test communications between the Touchscreen and the SMCSD10 Z as follows before permanently mounting the SMCSD10 Z Hold the SMCSD10 Z where you plan to install it Press the SMCSD10 Z Test button for 10 to 15 seconds The SMCSD10 Z sends a signal to the Touchscreen At the Touchscreen verify the sig...

Страница 5: ...e At the Settings Menu touch Security Alarm Tests Follow the Touchscreen s provided directions to place it into Test Mode C To generate a test alarm press and hold Test Button for 15 seconds An alarm message is sent to the Touchscreen The Touchscreen alarm will sound as each sensor is tested D Once completed exit Test Mode from the Touchscreen Using Smoke The SMCSD10 Z can be tested during install...

Страница 6: ...ng Zone Event History on this page To bypass a zone A With the system disarmed tap the Security app on the Home screen B Tap the Turn Zone Off button for the smoke detector The Turn Zone Off button changes to Turn Zone On C When the system is disarmed the Security Status header shows that some zones have been bypassed 12 Deleting a Sensor Deleting a sensor from the premises removes it as a monitor...

Страница 7: ...F until the SMCSD10 Z is serviced To place the SMCSD10 Z in diagnostic mode A Press the Test Button on the smoke detector for 5 seconds When the test starts the smoke detector LED flashes 1 to 9 times B Count the LED flashes and see the table below to determine the status of the smoke detector sensitivity and any action to take Flash Meaning Steps to Take 1 Unserviceable hardware fault Reset unit ...

Страница 8: ... Replace the batteries using the directions in section 5 of this guide 14 Troubleshooting The SMCSD10 Z does not power up properly or reports low battery Be sure the batteries are fully seated within the battery compartment and the polarity is correct Check the battery voltage 3 0 VDC nominal Touchscreen does not respond Follow the instructions in section 9 of this guide to test the SMCSD10 Z link...

Страница 9: ... Battery Life 5 years typically USensor Photoelectric Sensitivity 2 2 1 3 ft Drift Compensation Adj 0 5 ft max Heat Detection Fixed 135 F 5 F 57 2 C 2 8 C Heat Rate of Rise 15 F min 105 F 8 3 C min 40 6 C Low Battery Beep 1 every 45 seconds RF Wireless Frequency 2 4 GHz Weight w battery 0 20 lbs 0 09 kg Dimensions 5 6 x 2 4 14 2cm x 6 1cm Storage temperature 4 to 140 F 20 to 60 C Operating environ...

Страница 10: ...codes and standards or by the authority having jurisdiction NFPA 72 8 1 4 1 3 2 Detection in New Apartment Buildings Approved single station smoke alarms shall be installed in accordance with 7 6 2 10 of NFPA 101 outside every sleeping area in the immediate vicinity of the bedrooms and on all levels of the dwelling unit including basements 101 18 3 4 4 2 For exceptions refer to this section of NFP...

Страница 11: ...ediately Don t stop to pack or search for valuables In heavy smoke hold your breath and stay low crawl if necessary The clearest air is usually near the floor If you have to go through a closed door carefully feel the door and door knob to see if undue heat is present If they seem cool brace your foot against the bottom of the door with your hip against the door and one hand against the top edge O...