Current studies show smoke detectors may not 
awaken all sleeping individuals. It is the 
responsibility of individuals in the household that 
are capable of assisting others to provide aid to 
those who may not be awakened by the alarm, 
or to those who may be incapable of safely 
evacuating the area unassisted. 

5   

Installing / Replacing Battery 

The SMCSD10-Z comes with two 3V Lithium 
CR123A batteries preinstalled. When you need to 
replace them use the following procedure. Use 
batteries specified in this document 
specifications or as listed on the battery 
compartment cover. Use of a different battery 
can have a detrimental effect on the detector 
operation. Constant exposures to high or low 
humidity can reduce battery life. 

A.

 

Remove the SMCSD10-Z from the mounting 
base (see section 7 of this guide). Slide the 
battery compartment cover away from the 
SMCSD10-Z to unsnap it and lift it off.  

  

B.

 

If you are replacing batteries, remove and 
dispose of the batteries appropriately. Wait 

30 seconds after removal before continuing 
to the next instruction. 

C.

 

Observing proper polarity as indicated in the 
battery compartment, insert two new 3V 
lithium batteries into the SMCSD10-Z battery 
compartment and replace the battery 
compartment cover. 

Note:

 

Use two new batteries when replacing old 

batteries. Do not replace with batteries that were 
used previously. 

 

D.

 

Reattach the SMCSD10-Z to the mounting 
base and test the system. 

E.

 

The SMCSD10-Z ships with a dust cover for 
protection on construction sites with dusty 
environments. If your product is new, remove 
the red plastic dust cover from the SMCSD10-
Z. 

 

6   

Pairing with Touchscreen 

Each SMCSD10-Z is programmed with a unique ID 
when manufactured. The unique ID is enrolled 
into the Touchscreen at the time of installation, 

allowing the SMCSD10-Z to communicate with 
that specific Touchscreen. 

A.

 

At the Home screen, touch the Settings 
widget.  

B.

 

When the Keypad screen appears, touch the 
numbers to enter your keypad code.  

C.

 

At the Settings menu, use the keypad to 
enter the Installer Code (this code is the 
same for all Touchscreen installed by your 
company).  

D.

 

At the Technician keyboard pad, enter your 
Technician ID and touch 

Done

.  

E.

 

At the Technician Settings menu, select 

Sensors & Zones > Add a Sensor/Zone

. The 

Locating Sensors screen appears. 

F.

 

Click 

Next

. The system scans the premise for 

wireless sensors that can be added, which 
must meet the following requirements:  

Not currently paired with another 
Touchscreen. 

Is active. New sensors must be activated as 
follows: Turn the back cover counter-
clockwise to remove. Open the battery 
compartment. Removing the battery 
activation tab to power on the unit. 

Defaulted if previously paired. To default 
the sensor, see section 9 of this guide. 

G.

 

Follow the system prompts to complete the 
add process. Trip the sensor by pressing and 
holding down the Test Button on the front 
cover of the detector for 10 seconds. 

Содержание SMCSD10-Z

Страница 1: ...Pre installation Considerations Install the SMCSD10 Z in accordance with the National Fire Protection Association s NFPA Standard 72 Chapters 2 and 8 Depending on the application you may need to reference other chapters of NFPA 72 or NFPA 101 Choosing an Installation Location When choosing an installation location consider Use of structure and type of construction Contents you want to protect and ...

Страница 2: ...t smoke from reaching a smoke detector Within 10 feet 3 m of fluorescent light fixtures Not suitable for outdoor use WARNING LIMITATIONS OF SMOKE DECTECTORS The SMCSD10 Z Smoke Detector does not contain a built in audio alarm It is not intended for stand alone use it MUST be used with an approved Touchscreen Wireless smoke detectors are very reliable but may not work under all conditions No fire a...

Страница 3: ...atteries Do not replace with batteries that were used previously D Reattach the SMCSD10 Z to the mounting base and test the system E The SMCSD10 Z ships with a dust cover for protection on construction sites with dusty environments If your product is new remove the red plastic dust cover from the SMCSD10 Z 6 Pairing with Touchscreen Each SMCSD10 Z is programmed with a unique ID when manufactured T...

Страница 4: ...SMCSD10 Z Add the SMCSD10 Z to the Touchscreen before physically mounting it in the desired location A Test communications between the Touchscreen and the SMCSD10 Z as follows before permanently mounting the SMCSD10 Z Hold the SMCSD10 Z where you plan to install it Press the SMCSD10 Z Test button for 10 to 15 seconds The SMCSD10 Z sends a signal to the Touchscreen At the Touchscreen verify the sig...

Страница 5: ...e At the Settings Menu touch Security Alarm Tests Follow the Touchscreen s provided directions to place it into Test Mode C To generate a test alarm press and hold Test Button for 15 seconds An alarm message is sent to the Touchscreen The Touchscreen alarm will sound as each sensor is tested D Once completed exit Test Mode from the Touchscreen Using Smoke The SMCSD10 Z can be tested during install...

Страница 6: ...ng Zone Event History on this page To bypass a zone A With the system disarmed tap the Security app on the Home screen B Tap the Turn Zone Off button for the smoke detector The Turn Zone Off button changes to Turn Zone On C When the system is disarmed the Security Status header shows that some zones have been bypassed 12 Deleting a Sensor Deleting a sensor from the premises removes it as a monitor...

Страница 7: ...F until the SMCSD10 Z is serviced To place the SMCSD10 Z in diagnostic mode A Press the Test Button on the smoke detector for 5 seconds When the test starts the smoke detector LED flashes 1 to 9 times B Count the LED flashes and see the table below to determine the status of the smoke detector sensitivity and any action to take Flash Meaning Steps to Take 1 Unserviceable hardware fault Reset unit ...

Страница 8: ... Replace the batteries using the directions in section 5 of this guide 14 Troubleshooting The SMCSD10 Z does not power up properly or reports low battery Be sure the batteries are fully seated within the battery compartment and the polarity is correct Check the battery voltage 3 0 VDC nominal Touchscreen does not respond Follow the instructions in section 9 of this guide to test the SMCSD10 Z link...

Страница 9: ... Battery Life 5 years typically USensor Photoelectric Sensitivity 2 2 1 3 ft Drift Compensation Adj 0 5 ft max Heat Detection Fixed 135 F 5 F 57 2 C 2 8 C Heat Rate of Rise 15 F min 105 F 8 3 C min 40 6 C Low Battery Beep 1 every 45 seconds RF Wireless Frequency 2 4 GHz Weight w battery 0 20 lbs 0 09 kg Dimensions 5 6 x 2 4 14 2cm x 6 1cm Storage temperature 4 to 140 F 20 to 60 C Operating environ...

Страница 10: ...codes and standards or by the authority having jurisdiction NFPA 72 8 1 4 1 3 2 Detection in New Apartment Buildings Approved single station smoke alarms shall be installed in accordance with 7 6 2 10 of NFPA 101 outside every sleeping area in the immediate vicinity of the bedrooms and on all levels of the dwelling unit including basements 101 18 3 4 4 2 For exceptions refer to this section of NFP...

Страница 11: ...ediately Don t stop to pack or search for valuables In heavy smoke hold your breath and stay low crawl if necessary The clearest air is usually near the floor If you have to go through a closed door carefully feel the door and door knob to see if undue heat is present If they seem cool brace your foot against the bottom of the door with your hip against the door and one hand against the top edge O...