- 31 -
3.4 Parameter setting
Initial setting for the basic parameters
Refer to the controller’s (LEC series) operation manual for detail.
As the “basic parameter” is unique data of each actuator, if an actuator other than the electric slide table
Note1) Become effective after restarting the controller.
Note2) If the stroke value entered is equivalent to the product stroke, an alarm may be generated by an
overshoot.
Note3) Please enter “1” in the “stroke (+)” when you make the direction to the origin point CW, and enter
“(-1) (product stroke) -1” in the “stroke (-)”.
Note4) The origin offset is used for the “return to origin”. / See 2) Origin offset on p.33
Description (Extract)
Initial input value
Input range
Controller ID
1
1 to 64 Note 1)
IO pattern
1:64
-
Acceleration /
deceleration pattern
1: Trapezoid -
motion
-
S-motion ratio
0
-
Stroke (+) note2 )3)
Product 1
10000
Stroke (-) note2 )3)
-1.00
-10000
Maximum speed
Max. speed of each
product
Step data input limit:
Max. speed of each product
Maximum acceleration /
deceleration
5000 to
5000
Default In positioning
0.5
0.5 to product stroke
Origin offset note4)
0.00
Not changeable
70
(LESH**)
30 to 70
75(LESH8*A)
50 to 75
Maximum pushing force
100
(LESH16*A,LESH25*A)
50 to 100
Parameter protect
1:
StepData
Changeable parameter
1: StepData, 2: Common
Enable switch
2: Disable
Select 1:Enable or 2:Disable when using a teaching box
Model name
Part no. of each
product
Only the English characters and numbers are
changeable.
W-area output end 1
0.00
-
W-area output end 2
0.00
-
Origin correction data
0.00
-