- 20 -
3.3 Step data setting
Refer to the operation manual of the controller (LEC series) for details.
This operation manual specifies the electric slide table, if an actuator other than the electric slide table is
used, refer to the operation manual of each type of actuator and controller (LEC series) regarding the
description of step data.
Caution
The actuator body and controller are sold as a package.
If when only the actuator is purchased separately, confirm that the combination of the controller, which
you have and the actuator is compatible.
/
See 5.3
Caution(1) on p.38
<Be sure to check the following before use.>
(1) Check that actuator label for model number.
This matches the controller.
(2) Check Parallel I /O configuration matches (NPN or PNP).
Positioning operation
In the positioning operation, the electric slide table transfers to and stops at the target position.
The following image shows the set items and operation.
<Confirmation of reaching of target position at the positioning operation>
When the table of actuator reaches the range of the target position, the output signal
【
INP
】
(in position) is outputted.
When the table of actuator enters the range of
【
in position
】
, the INP output signal turns on.
Caution
Please use by "Pushing Mode" when you make it Push or clamp.
The product might be damaged by the impact when using it by "Positioning Mode".
/ See 6.2
Caution2 on p.41
(1)
(2)
LESH8RJ-50
NPN
Speed
Acceleration
Deceleration
Speed
ON
INP output
Position
ON
OFF
In pos