5 Adjustments
5-6
(4) Related Parameters
Use the following parameters to change the monitor factor and the offset.
Pn550
Analog Monitor 1 Offset Voltage
Speed
Position
Torque
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.1 V
0
Immediately
Setup
Pn551
Analog Monitor 2 Offset Voltage
Speed
Position
Torque
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
0.1 V
0
Immediately
Setup
Pn552
Analog Monitor Magnification (
×
1)
Speed
Position
Torque
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
×
0.01
100
Immediately
Setup
Pn553
Analog Monitor Magnification (
×
2)
Speed
Position
Torque
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
-10000 to 10000
×
0.01
100
Immediately
Setup