1 Outline
1
-
15
1.8.2 Installation Conditions for Applicable Standards
Applicable
Standards
EN50178, EN55011/A2 group1 classA, EN61000-6-2, EN61800-3,
EN61800-5-1, EN954-1, IEC61508-1 to 4
Operating
Conditions
Overvoltage Category: III
Pollution degree: 2
Protection class: IP10
Installation
Conditions
Low Voltage Directive:
Satisfy the conditions outlined in
1.8.3 Conditions Corresponding to Low Voltage Directive
of this manual.
EMC Directive:
Certification is required after installation in the user’s machine under the conditions outlined in
3.8.3 EMC Installation
Conditions
of this manual.
1.8.3 Conditions Corresponding to Low Voltage Directive
To adapt DRIVERs to the Low Voltage Directive, make sure that the following environmental conditions are met.
• Installation category: III
• Pollution degree: 2
• Protection class: 10
• Altitude: 1000 m max.
Be sure to install a fuse for the main circuit power-supply as well as meeting these environmental conditions. To choose
the fuse capacity, refer to
3.1.2 Using a Standard Power Supply (Three-phase 200 V)
.
Содержание LECYU Series
Страница 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Страница 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Страница 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Страница 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Страница 99: ...3 Wiring and Connection 3 45 4 Cable with Connector for CN8 Model LEC JZ CVSAF External Dimensions Units mm ...
Страница 143: ...4 Operation 4 44 ...