4 Operation
4-36
4.7.3 Battery Replacement
If the battery voltage drops to approximately 2.7 V or less, an absolute encoder battery error alarm (A.830) or
an absolute encoder battery error warning (A.930) will be displayed.
If this alarm or warning is displayed, replace the batteries using the following procedure.
Use Pn008.0 to set either an alarm (A.830) or a warning (A.930).
Parameter
Meaning
When
Enabled
Classification
Pn008
n.
口口口
0
[Factory setting]
Outputs the alarm A.830 when the battery voltage
drops.
After restart
Setup
n.
口口口
1
Outputs the warning A.930 when the battery voltage
drops.
•
If Pn008.0 is set to 0, alarm detection will be enabled for 4 seconds after the ALM signal outputs max. 5 sec- onds
when the control power is turned ON.
No battery-related alarm will be displayed even if the battery voltage drops below the specified value after these 4
seconds.
•
If Pn008.0 is set to 1, alarm detection will be always enabled after the ALM signal outputs max. 5 seconds when
the control power supply is turned ON.
Control
power
Alarm status
Normal status
5 s max.
4 s
Alarm A.830
(Pn008.0 = 0)
Warning A.930
(Pn008.0 = 1)
Battery
voltage being
monitored
Battery voltage
being monitored
(1) Battery Replacement Procedure
1.
Turn ON the control power supply of the DRIVER only.
2.
Open the battery case cover.
Open the cover.
Содержание LECYU Series
Страница 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Страница 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Страница 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Страница 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Страница 99: ...3 Wiring and Connection 3 45 4 Cable with Connector for CN8 Model LEC JZ CVSAF External Dimensions Units mm ...
Страница 143: ...4 Operation 4 44 ...