- 54 -
Over speed
(1-144)
D
RESET
SVON
Input
*1)
<Contents>
The motor speed exceeds a specific level due to an external
force, etc.
<Countermeasure>
Make improvements such that the motor speed will not exceed
the maximum speed of the electric actuator.
Caution
Please refer to the manual or the catalogue of the electric
actuator for the maximum speed of the electric actuator.
Over motor Vol
(1-145)
D
RESET
SVON
Input
*1)
<Contents>
The motor power supply voltage is out of range. During [SVON].
<Countermeasure>
Make sure that the voltage supplied to the motor power (M24V)
of the controller is within specification.
Caution
If the power supply is “inrush current control type”, a voltage
drop may cause an alarm during acceleration/ deceleration.
<Contents>
The alarm may be increased by regenerative power depending
on the method of operation of the electric actuator.
<Countermeasure>
Make sure that the operating conditions are within the
specifications.
Caution
Please refer to the manual or the catalogue of the electric
actuator for the method of operation of the electric actuator.
Over Temp.
(1-146)
D
RESET
SVON
Input
*1)
<Contents>
The temperature around the power element of the controller is
too high.
<Countermeasure>
Make improvements so that the temperature around the
controller is kept appropriate.
Over Crtl Vol
(1-147)
D
RESET
SVON
Input
*1)
<Contents>
The control power supply voltage within the controller is out of
a range.
<Countermeasure>
Make sure that the voltage supplied to the control power
(C24V) of the controller is appropriate.
Caution
If one power supply is commonly used for the control power
and the motor power, or the power supply is inrush current
restraining type, a power voltage drop may be caused due to
a voltage drop during the acceleration/ deceleration.
<Contents>
The alarm may be increased by regenerative power depending
on the method of operation of the electric actuator.
<Countermeasure>
Make sure that the operating conditions are within the
specifications.
Caution
Please refer to the manual or the catalogue of the electric
actuator for the method of operation of the electric actuator.