Manifold Specifications
Type
Lead wire
Fieldbus (IO-Link)
*
1
Manifold type
Plug-in connector connecting base
SUP/EXH port type
Common SUP/EXH
Valve stations
2 to 16 stations
Internal wiring
Positive common
Negative common
(Refer to “Electrical Wiring Specifications” on page 14.)
Negative common
Port size
1(P), 5/3(EA/EB) port
G1/2 (Based on ISO 16030)
4(A), 2(B) port
G1/4 (Based on ISO 16030)
Enclosure
IP69K
(Based on IEC/EN 60529/ISO 20653)
External parts material
Resin parts: PA, Metal parts: Stainless steel 316, Rubber parts: EPDM
*
1 Refer to page 30 for the Fieldbus type for output (EX430 series) specifications.
Port size
Flow rate characteristics
Weight: g
*
1
(n: Number of stations)
1, 5, 3
(P, EA, EB)
4, 2
(A, B)
1
R
4, 2 (P
R
A, B)
4, 2
R
5, 3 (A, B
R
EA, EB)
C [dm
3
/(s·bar)]
b
C [dm
3
/(s·bar)]
b
G1/2
G1/4
6.80
0.31
7.64
0.23
227 n + 1070
Lead wire type
227 n + 500
Fieldbus type
*
1 Weight without fittings. For when a lead wire type cable is 5 m. Add the weight of the valves to be mounted from the table below to find the total weight.
Valve model
Type of actuation
Weight [g]
JSY5
m
03-H
2-position
Single
86
Double
96
3-position
Closed center
106
Exhaust center
Pressure center
4-position
Dual 3-port
92
Manifold Flow Rate Characteristics/Weight
Valve Weight
Response Time
Valve model
Response time [ms]
*
1
Z type
U type
JSY5103-H
40
32
JSY5203-H
19
19
JSY53/4/503-H
46
44
JSY5A/B/C03-H
38
*
2
29
*
2
*
1 Based on dynamic performance test, JIS B 8419:2010 (Coil tempera-
ture: 20°C, at rated voltage)
*
2 There will be an approx. 10 ms delay on the 2(B) port side due to the
length of the pilot passage.
Connector Wiring Layout
For both Fieldbus and lead wire types, additional valves are sequentially assigned pins on the connector.
This makes it completely unnecessary to disassemble the connector unit.
M
Single solenoid valve is installed to all double wiring. (Double wiring specification)
(Manifold specification sheet is not necessary.)
*
These diagrams are for the purpose of explanation, and differ from the actual connector wiring.
SOL.b
SOL.a
Station 3
SOL.a
Unused terminal
Station 2
SOL.a
SOL.b
Station 1
Double solenoid
Station 3
Common (+, –)
Single solenoid
(Double wiring)
Station 2
Double solenoid
Station 1
Solenoid
Connector side
(Lead wire)
7
JSY5000-H
Series