Protective class
class
#
(Mark: )
How to Order Valves
q w e r t
y u
Clean design manifold valve
identification symbol
JSY5 1 0 3
5 U H
t
Coil type
Nil
Standard
T
*
1
With power-saving circuit (Continuous duty type)
*
1 “T” (With power-saving circuit) should be
ordered as made to order.
w
Body type
0
Base mounted (For plug-in)
y
Rated voltage
5
24 VDC
e
Pilot valve exhaust method
3
Pilot valve common exhaust
r
Pilot type
Nil
Internal pilot
R
*
1
External pilot
*
1 The external pilot specification should
be ordered as made to order.
How to Order Manifold Assembly
Example
(
JJ5SY5-H11L105-
m
)
3
Stations
D side
U side
2
1
2-position double (24 VDC)
JSY5203-5U-H (3 sets)
2-position single (24 VDC)
JSY5103-5U-H (2 sets)
Manifold base (5 stations)
JJ5SY5-H11L105-05B-B10
q
Type of actuation
1
2-position
Single
2
Double
3
3-position
Closed center
4
Exhaust center
5
Pressure center
A
*
1
4-position
dual 3-port
N.C./N.C.
B
*
1
N.O./N.O.
C
*
1
N.C./N.O.
*
1 External pilot specification is not applicable
for 4-position dual 3-port valves.
u
Light/surge voltage suppressor
Symbol With light Surge voltage
suppressor
Common
specification
U
V
V
Non-polar
Z
Positive common
NZ
Negative common
*
Only “Z” and “NZ” types are available with a power-
saving circuit.
*
For fieldbus type manifold, select non-polar (U) or
negative common (NZ).
Caution
¡
If the valve will be continuously ener-
gized, please be sure to use the power-
saving circuit (continuous duty type).
Refer to Made to Order on page 33.
· For the valve arrangement, the valve closest to the D side is considered the 1st
station.
· Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
Ordering example
JJ5SY5-H11L105-05B-B10 ···· 1 set (Type H11 5-station manifold base part no.)
*
JSY5103-5U-H ····················· 2 sets (2-position single part no.)
*
JSY5203-5U-H ····················· 3 sets (2-position double part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
This is an IP69K compliant
product. The manifold and
valves are ordered as a set.
Caution
This is an IP69K compliant product. The
manifold and valves are ordered as a set.
Caution
12
Clean Design Manifold Valve
JSY5000-H
Series
JSY5000-H
V
alve
Sub-plate
Manif
old
Exploded Vie
w
Sub-plate
Exploded Vie
w
Fittings,
Plugs,
Tube
Releasing T
ools
Manif
old
Options
Specific Pr
oduct
Precautions
Made to Or
der
EX430