Position indicator LED
SI unit holding screw: 2 locations
Hexagon bolt with flange (M3)
Tightening torque: 0.8 N·m
IO-Link connector
Valve connector
161
(41.1)
27
How to Order SI Units
Specifications
Dimensions
Fieldbus System: For Output
EX430
Series
EX430
EX430 S IL1
Communication protocol
Symbol
Protocol
Output polarity
Communication connector
Manifold symbol
IL1
IO-Link
Source/PNP (Negative common)
M12
*
1
SKAN
*
1 The M12 connector is located on the SUP/EXH block on the manifold D side.
Model
EX430-SIL1
Applicable
system
Protocol
IO-Link (Class B)
Version
V1.1
Configuration file
*
1
IODD file
I/O occupation area (Inputs/Outputs)
0/32, 16/32
*
2
Communication speed
COM3/COM2
*
2
Communication connector specification
M12
*
3
Power supply
for control
Power supply voltage
18 to 30 VDC
Internal current consumption
50 mA or less
Power supply for output
Power supply voltage
22.8 to 26.4 VDC
Output
Output type
Source/PNP (Negative common)
Number of outputs
32
Load
Solenoid valve with surge voltage suppressor of
24 VDC, 0.4 W or less (SMC)
Supplied voltage
24 VDC
Supplied current
Max. 0.54 A
Environmental
resistance
Operating temperature range
−10 to 50
°
C
Operating humidity range
35% to 85% RH (No condensation)
Withstand voltage
500 VAC for 1 minute between terminals and housing
Insulation resistance 10 M
Ω
or more (500 VDC measured via megohmmeter) between terminals and housing
Standards
CE marking (EMC directive/RoHS directive)
Weight
100 g
*
1 The configuration file can be downloaded from the SMC website: https://www.smcworld.com
*
2 A selection can be made using the setting switch.
*
3 The M12 connector is located on the SUP/EXH block on the manifold D side.
30
JSY5000-H
V
alve
Sub-plate
Manif
old
Exploded Vie
w
Sub-plate
Exploded Vie
w
Fittings,
Plugs,
Tube
Releasing T
ools
Manif
old
Options
Specific Pr
oduct
Precautions
Made to Or
der
EX430