46
Err4: Backup Error
Content
: After power supply is on or Reset signal is inputted, backup checking is
conducted, error is detected during output. Each and individual data is
checked through backup checking. Once, error is detected, clear the error and
at the same time, data will be deleted too.
Err41
・・・
Preset Data Error
When this error appears, input data will be deleted. Re-input is
required.
Err42
・・・
Program Data Error
When this error appears, input position
’s data will be deleted.
Re-input is required.
Err43
・・・
Learning Data Error
When this error appears, learning data will be deleted and lead to
the operation of predictive control (retries will perform again).
When errors appear, re-entry of data is required.
Solution
: Press ON (UP or DOWN).
Countermeasure
: Check below 5 points and execute accordingly.
1 Check whether reset is executed during the execution of controller or during
motion.
Besides that, please verify wiring and sequence of the program.
2 Verify whether AC100V
’s deviation is within the tolerance level,
±
15% (AC85
~
115V).
3 Verify the power supply (AC100V) has been toggled within 20ms.
4 Check whether controller
’s FG (frame ground) is being connected to earth.
5 Verify that there is no moving signal feedback from sensor while the power
is being cut off.
Err5: Data Error
Content
: 1 During presetting of data, over stating the cylinder
’s stroke, or under
stating the moving distance of cylinder (less than 5mm), error will be
shown.
2 During operation, error will also appear, when moving distance is less
than 5mm. However, if the stop position is still within the tolerance of next
setting point, stop point will be determined and accepted.
<Example>
After inputting start, cylinder will stop at the position.
Solution
: During programming, press ON (UP or DOWN).
During moving state, press either ON or RESET.
Countermeasure
: If situation 1 and 2 occur, please change the program accordingly.
Err6: Learning Error
Content
: The stopping position is before the braking position.
50
Setting Point
Next Setting Point
57
Tolerance±4.0
Cylinder Stopping Position 53.1
Stop within the range
Tolerance±4.0