During initial setup, predictive control is executing.
Hence, it is suggested to set the maximum retries to
5 or above.
After setting of maximum retries, press WRITE to
switch to the next input condition. The display will
indicate PRG STEP P4 and the current cylinder bore
size, which is blinking.
Next, enter appropriate cylinder bore size.
Setting value will vary as shown below.
Note:
Monosashi-kun with Brake (CE
2)’s bore size setting
range from
φ
40 to
φ
100.
After setting of cylinder bore size, press WRITE to
switch to the next input condition. The display will
indicate PRG STEP P5 and the current load rate,
which is blinking.
Next, enter correct load rate.
<Calculation>
Load
÷
Cylinder Pushing Force
×
100
Setting value will vary as shown below.
After the above setting, press WRITE to switch to the
next input condition.
The display will indicate PRG STEP P6 and the
current number of brake operation
The display number shows the operation number of
brake assembly that had been activated. 1 unit
represents 10,000.
Setting is not required.
PRG
STEP P4
″
″
″
〟
40
Blinking
DOWN
UP
63
80
100
25
32
40
50
PRG
STEP P5
″
″
″
〟
0
Blinking
DOWN
UP
40
50
0
10
20
30
PRG
STEP P6
0.0
No blinking.
Note:
Change the brake assembly, when
the counter reaches 300.0.
(refer to P.41 11-2)