15 Technical Data
SMA Solar Technology AG
Operating manual
SHP-US-20-BE-en-10
91
Number of fans
3
Enclosure degree of protection according to
UL 50
Type 4X
Protection class
I
National standards and approvals,
as per 03/2019
UL 62109-1, IEEE 1547, CAN/CSA-C22.2 No.
62109, FCC Part 15 (Class A)
Climatic Conditions
Installation in accordance with IEC 60721-3-4, Class 4K4H
Extended temperature range
-25°C to +60°C (-13°F to +140°F)
Extended humidity range
0% to 100%
Threshold for relative humidity, non-condensing
100 %
Extended air pressure range
79.5 kPa to 106 kPa
Transport in accordance with IEC 60721-3-4, Class 2K3
Temperature range
-40°C to +70°C (-40°F to +158°F)
Equipment
DC connection
Terminal lugs
AC terminal
Screw terminals
Torques
Screws of mounting bracket (M8x105, TX40)
12 Nm ± 2 Nm (106 in-lb ± 17.7 in-lb)
Screws for attaching the inverter to the mounting
brackets (M8x16, TX40)
12 Nm ± 2 Nm (106 in-lb ± 17.7 in-lb)
Screws for attaching the connecting plate to the
inverter (M8x70, TX40)
8 Nm ± 0.5 Nm (71 in-lb ± 4 in-lb)
Screws AC terminals L1, L2 and L3 (AF8)
24 Nm (216 in-lb)
Screws AC terminal of grounding conductor
(AF5)
10 Nm (90 in-lb)
Screws for attaching equipment grounding con-
ductor of PV modules
6 Nm ± 0.3 Nm (53 in-lb ± 2.65 in-lb)
Screws for attaching terminal lugs of DC con-
nection (AF16)
24 Nm ± 2 Nm (212 in-lb)
Enclosure lid screws (TX25)
6 Nm ± 0.3 Nm (53 in-lb ± 2.65 in-lb)