12 Troubleshooting
SMA Solar Technology AG
Operating manual
SHP-US-20-BE-en-10
75
Event number
Message, cause and corrective measures
10255
[Interface]: Network load OK
The network load has returned to a normal range after being busy.
10282
[User group]-Login via [protocol] locked
After several incorrect login attempts, login has been blocked for a limited
time. In this case, the User login will be blocked for 15 minutes, the
Grid Guard login for 12 hours.
Corrective measures:
• Wait until the given time has expired and then retry login.
10339
Webconnect enabled
10340
Webconnect disabled
10341
Webconnect error: no connection
10343
Webconnect error: Default gateway not configured
10344
Webconnect error: DNS server not configured
10345
Webconnect error: No reply to DNS request |xx|
10346
Webconnect error: Unknown SIP proxy |xx|
10347
Webconnect error: Unknown STUN server [xx]
10348
Webconnect error: No reply to request to STUN server
10349
Webconnect error: No reply to SIP option packs
10350
Webconnect error: Registration rejected by SIP registrar
10351
Webconnect error: Unknown SIP registrar |xx|
10352
Webconnect error: Faulty communication
10353
Webconnect error: registration of the SIP registry has not responded
10502
Active power limited AC frequency
10517
Dynamic active power limitation started.
10518
Dynamic active power limitation terminated.
10520
Supplied power: |xx| W (permitted value: |xx| W)
10521
Active power was limited today for |xx| minutes.
10525
Inverter does not respond to active power limitation.
10528
Login for NSD function on device |xx| failed
10901
Start self-test [xx]
10902
Uac RPro [xxx] V