12 Technical Data
SMA Solar Technology AG
Operating manual
EDML-10-BE-en-13
57
12 Technical Data
Communication
SMA devices
• incl. I/O systems and power analyzers
Max. 200 devices
Max. 10 devices (e.g. Ethernet, Modbus TCP)
Connections
Voltage supply
3-pole terminal
Network (LAN)
2 x 10/100/1000 Mbps (RJ45)
Serial interface
1 x RS232, D-sub 9
3)
USB
1 x USB 3.0, type A
2 x USB 2.0, type A
Digital inputs
4 x DI, 0 V DC to 30 V DC
Digital outputs
4 x DO, 0 V DC to 30 V DC
Voltage supply
Supply voltage
9 V DC to 36 V DC, typ. 24 V DC (UPS
4)
> 5s )
Input voltage range
9 V DC to 36 V DC
Electric current/power consumption
2 A at 9 V DC (typ. 18 W)
Ambient Conditions in Operation
Ambient temperature
-40°C to +70°C
Permissible range for relative humidity (non-con-
densing)
5% to 95%
Maximum operating altitude above mean sea
level (MSL)
3000 m (≥70 kPa)
Degree of protection
IP20
General Data
Dimensions without wall mounting bracket (W x
H x D)
150 mm x 120.2 mm x 48.8 mm
Weight
940 g
Mounting location
Indoors
Mounting type
Top-hat rail mounting / wall mounting
Material type
Aluminum
3)
Prepared for RS485 converter e.g. the TCC-100I-T from Moxa Europe GmbH
4)
Operation only on uninterruptible power supply with potential-free contact