7 Commissioning
SMA Solar Technology AG
Operating manual
EDML-10-BE-en-13
37
☐ The connected Modbus devices must be configured to send their setpoints in cyclic intervals
(maximum cycle time: 1 minute; recommended cycle time: 1 second).
Restart at different system time
An NTP server must be available in the local network or via the Internet. If there is no NTP
server available, the time set in the web browser is used as system time. If the difference
between the time in the web browser and the system time is more than one minute, the time is
synchronized and the product restarted.
Configuring the network settings
1. To configure the network settings, select
Change the network configuration
. Observe that
the manual network configuration is set by default.
2. If the network settings are to be configured automatically via the DHCP server, select [
Yes
].
3. Configure network settings and confirm with [
Save
].
Starting the installation assistant
1. Select [
Continue
] on the login page of the user interface.
2. Create administrator account and select [
Next
]. Observe that only one user with administrator
authorization can be created on each Data Manager.
☑ The installation assistant will open.
3. Follow the installation assistant steps listed and make the settings appropriate for your system
(device registration, master or slave configuration, meter configuration, grid management
service).
☑ A successful commissioning is confirmed by a message.
7.4
Registering in Sunny Portal
Once you have carried out the commissioning on the user interface of the product, you can make
further system configurations in Sunny Portal. For this, all products of a system must be registered in
Sunny Portal.
The SMA Data Manager L only supports the Sunny Portal powered by ennexOS.
Profiles for data communication
Different profiles are available to control the intensity of data communication in the system. The
profiles can be edited in the system properties at any time in Sunny Portal to adjust the
intensity. Note that when switching from a low to a high intensity data communication, the
data from the past is not retroactively adjusted. The adjustment applies from the date of the
change. The following profile can be selected for data communication:
• High (default setting): Devices send all relevant data to the Sunny Portal every 5 minutes.
• Medium: Devices send all relevant data to the Sunny Portal every 15 minutes.
• Low: Devices send the most important data to the Sunny Portal 6 times per day.
Requirements:
☐ The product must be in operation and connected to the local network via an Internet router.
☐ The registration ID (RID), identification key (PIC) and the Internet address of the type label or
of other provided labels must be available.