OPERATING CONDITIONS & REQUIREMENTS 

 

 

 

Page 4 

 

OPERATING PRESSURE: min. 1,4 / max. 8,3 bar 

 

this system is configured to perform optimally at an operating 
pressure  of  3  bar  (±½  bar);  in  case  of  a  lower  or  higher 
operating  pressure  the  performance  may  be  affected 
negatively! 

 

check water pressure regularly. 

 

take  into  account  that  night  time  water  pressure  may  be 
considerably higher than day time water pressure. 

 

install  a  pressure  reducer  ahead  of  the  water  softener  if 
necessary. 

 
 

 

OPERATING TEMPERATURE: min. 2 / max. 48 °C 

 

do  not  install  the  water  softener  in  an  environment  where 
high  ambient  temperatures  (e.g.  unvented  boiler  house)  or 
freezing temperatures can occur. 

 

the  water  softener  cannot  be  exposed  to  outdoor  elements, 
such as direct sunlight or atmospheric precipitation. 

 

do not install the water softener too close to a water heater; 
keep  at  least  3  m  of  piping  between  the  outlet  of  the  water 
softener and the inlet of the water heater; water heaters can 
sometimes  transmit  heat  back  down  the  cold  pipe  into  the 
control valve; always install a check valve at the outlet of the 
water softener. 

 
 

 

ELECTRICAL CONNECTION: 230V-50Hz 

 

this water softener only works on 24VAC; it is equipped with a 
230/24V-50Hz transformer; always use it in combination with 
the supplied transformer. 

 

make sure to plug the transformer into a power outlet, which 
is installed in a dry location, with the proper rating and over-
current protection. 

 

 

 

Содержание Eco 17L

Страница 1: ...2013 Aquion Inc TM EN Slimline Rev2013 08 Technical Manual WATER SOFTENER...

Страница 2: ...ow diagrams Eco Page 12 Hydraulic flow diagrams Eco Page 13 Troubleshooting Page 14 Electrical wiring diagrams Page 16 Default parameter settings Page 17 Exploded view Slimline 11L 14L Page 18 Explode...

Страница 3: ...rtaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water softener make sure to che...

Страница 4: ...oiler house or freezing temperatures can occur the water softener cannot be exposed to outdoor elements such as direct sunlight or atmospheric precipitation do not install the water softener too close...

Страница 5: ...e application treated water 1 Install the 3 valve bypass system 2 Screw the connection kit with nuts onto the elbow connections of the water softener make sure to install the gasket seals Tighten the...

Страница 6: ...show some discoloration close the tap 7 Check the water softener and all hydraulic connections for leaks After the first regenerations of the water softener some slight discoloration of the treated wa...

Страница 7: ...the message In such case entering one of the programming levels can possibly solve the problem However if the problem persists professional service is required SERVICE MODE In service mode the display...

Страница 8: ...scroll button the display will show Press the up or down button to set the language 2 Press the scroll button again the display will show Press the up or down button to set the time of day 3 Press th...

Страница 9: ...aration Cycle 2 Cycle 2 Backwash Cycle 3 Brine draw slow rinse Cycle 3 Cycle 4 Fast rinse Cycle 5 7 Press the scroll button again the display will show Press the up or down button to set the type of w...

Страница 10: ...e calculated volume of softened water between regenerations Hardness display shows the setting of the water hardness Rsrv display shows the setting of the reserve capacity Regen display shows the sett...

Страница 11: ...rol valve and water conditioner salt The user should make sure that the brine cabinet is always kept full of water conditioner salt Therefore he should periodically check the salt level inside the bri...

Страница 12: ...HYDRAULIC FLOW DIAGRAMS ECO Page 12 SERVICE REFILL BRINE PREPARATION BRINE DRAW SLOW RINSE...

Страница 13: ...HYDRAULIC FLOW DIAGRAMS ECO Page 13 SERVICE REFILL BRINE PREPARATION BACKWASH BRINE DRAW SLOW RINSE FAST RINSE...

Страница 14: ...fails to draw brine Improper refill time setting Verify that refill time corresponds to the proper salt level and amount of resin Missing refill flow control Verify that refill flow control is instal...

Страница 15: ...or and or brine restrictor Clean injector and or brine restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line...

Страница 16: ...4VAC auxilliary contact closed during regeneration max 500mA refill solenoid white drain solenoid key pad ECO flow meter power lead 24VAC auxilliary contact closed during regeneration max 500mA refill...

Страница 17: ...56 5 1 f M3 L equals 2 9 d M3 L 2 When the Exchange capacity per liter resin is changed the refill cycle time needs to be adjusted accordingly Model Eco Resin 11 17 24 Hardness unit 1 f f f Exchange...

Страница 18: ...EXPLODED VIEW SLIMLINE 11L 14L Page 18...

Страница 19: ...rine well 47 cm 14 38536 Screw rivet brine well 15 H1016 4 Brine well cap bottom 16 72263 Twist lock clamp power cord 17 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 18 70971 Power cord 19 7276...

Страница 20: ...EXPLODED VIEW SLIMLINE 17L 24L 30L Page 20...

Страница 21: ...rine valve assembly 464 to be cut to length 13 BW3 5 088 Brine well 14 38536 Screw rivet brine well 15 H1016 4 Brine well cap bottom 16 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 17 72263 Twi...

Страница 22: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 22...

Страница 23: ...54 Spring clip 25 186 118 O ring brine plug 26 541 273 Brine plug 27 72467 Union gasket 2x 28 72542 Elbow inlet 29 19 19 Clip drain flow adjuster 30 186 134 O ring drain flow adjuster 2x 31 541 238 Dr...

Страница 24: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 24...

Страница 25: ...1 254 Spring clip 25 186 118 O ring brine plug 26 541 273 Brine plug 27 72467 Union gasket 2x 28 72542 Elbow inlet 29 19 19 Clip drain flow adjuster 30 186 134 O ring drain flow adjuster 2x 31 541 238...

Страница 26: ...2 72216 Valve head 3 541 300 G Drain flow control 2 0 gpm Eco 11L Eco 15L Eco 20L 541 300 J Drain flow control 2 6 gpm Eco 26L 4 185 115 1 O ring drain line adaptor 5 74018 Nut drain solenoid 6 74016...

Страница 27: ...Page 27...

Страница 28: ...vice flow rate 1 bar pressure drop m hr 2 3 2 3 2 1 1 9 2 0 Recommended maximum service flow rate m hr 3 1 1 1 4 1 7 2 4 3 0 Rinse water usage per regeneration Ltr 4 61 64 101 107 131 2 Indicative num...

Страница 29: ...capacity per kg salt m x d 23 Service flow rate 1 bar pressure drop m hr 2 3 2 1 2 1 Recommended maximum service flow rate m hr 3 1 1 1 7 2 4 Rinse water usage per regeneration Ltr 4 110 139 175 2 Ind...

Страница 30: ...Page 30...

Страница 31: ...Page 31...

Страница 32: ...AQUION INC Lammerdries Oost 30c B 2250 Olen Belgium 32 0 14 28 51 71 32 0 14 28 51 70 RPR RPM Turnhout BWT TVA VAT BE 0882 738 206 infobelgium eriewatertreatment com www eriewatertreatment com...

Страница 33: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 1 2 3 a 3 b...

Страница 34: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 4 a 4 b 5 a 5 b r 6...

Страница 35: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 7 8 a r 8 b r 8 c...

Страница 36: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 9 a 9 b 9 c r 10...

Отзывы: