ELECTRONIC CONTROL PANEL
Page 10
DIAGNOSTICS LEVEL
Besides of all programming parameters, a series of operating
parameters can be consulted in the diagnostics level;
particularly during a service intervention, these parameters
can be helpful to identify the cause of a problem or
malfunction
Before entering the programming mode, make sure
that the control valve is in the service mode.
Accessing the Diagnostics level
1.
Press the
scroll
button and hold it for 5 sec until the
display shows:
2.
Within 10 sec, press the
down
button; the display will
show:
You are now in the Diagnostics level.
Press the
scroll
button to advance to the next
diagnostics parameter.
Available diagnostics parameters
Regen X days ago
: display shows number of days since
last regeneration of the system.
In Srvc
: display shows total number of days that the
system is in service.
# of Regens
: display shows the total number of
regenerations that have taken place since installation.
TotVol
: display shows the total water usage through the
system since installation.
LastRgn@
: display shows the water usage at the
moment of the last regeneration.
InstFlow
: display shows the instantaneous flow rate.
AvgVol
: display shows the average daily water usage.
Capacity
: display shows the calculated volume of
softened water between regenerations.
Hardness
: display shows the setting of the water
hardness.
Rsrv
: display shows the setting of the reserve capacity.
Regen @
: display shows the setting of the time of
regeneration.
Override
: display shows the setting of the number of
days between regenerations.
Cycle X
: display shows the setting of the length of the
corresponding regeneration cycle.
Units
: display shows that control is programmed for
Metric units.
MTR
: display shows the setting of the water meter.
Capacity
: display shows that control is programmed for
hardness setting.
Regen
: display shows the setting of the regeneration
mode.
Valve Type
: display shows the valve type setting.
MP Resets
: display shows the number of resets of the
microprocessor (
for factory purpose only
).
Memory Reset
: display shows the number of corrupt
memory start-ups (
for factory purpose only
).
EZ3P5e EZ3PB r11
: display shows the software version
(
for factory purpose only
).
CapToUse
: display shows the remaining capacity.
Fill
: display shows the refill time used for the previous
regeneration.
Reserve
: display shows the calculated reserve capacity.
Exiting the Diagnostics level
1.
If no button is pressed within 5 minutes, the
microprocessor will exit the diagnostics level end return
to the service mode.
2.
Press the
scroll
button repeatedly until the display
shows:
Press the
up
or
down
button to exit the
diagnostics level.
Exit
Regen XXdays ago
System Check
Содержание Eco 17L
Страница 1: ...2013 Aquion Inc TM EN Slimline Rev2013 08 Technical Manual WATER SOFTENER...
Страница 12: ...HYDRAULIC FLOW DIAGRAMS ECO Page 12 SERVICE REFILL BRINE PREPARATION BRINE DRAW SLOW RINSE...
Страница 13: ...HYDRAULIC FLOW DIAGRAMS ECO Page 13 SERVICE REFILL BRINE PREPARATION BACKWASH BRINE DRAW SLOW RINSE FAST RINSE...
Страница 18: ...EXPLODED VIEW SLIMLINE 11L 14L Page 18...
Страница 20: ...EXPLODED VIEW SLIMLINE 17L 24L 30L Page 20...
Страница 22: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 22...
Страница 24: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 24...
Страница 27: ...Page 27...
Страница 30: ...Page 30...
Страница 31: ...Page 31...
Страница 33: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 1 2 3 a 3 b...
Страница 34: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 4 a 4 b 5 a 5 b r 6...
Страница 35: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 7 8 a r 8 b r 8 c...
Страница 36: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 9 a 9 b 9 c r 10...