START-UP
Page 6
PRESSURIZING
1.
Make sure the bypass system is in 'bypass' position.
2.
Make sure the electronic controller of the water
softener is in service mode.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the water
softener and let the water run for a few minutes until all
air is purged and all foreign material that may have
resulted from the installation is washed out; close the
tap.
5.
Gently pressurize the water softener, by putting it into
service:
factory bypass:
1.
open the 'outlet' valve;
2.
slowly open the 'inlet' valve.
3-valve bypass:
1.
close the 'bypass' valve;
2.
open the 'outlet' valve;
3.
slowly open the 'inlet' valve.
6.
After 2-3 minutes, open a cold treated water faucet
nearby the water softener and let the water run for a
few minutes until all air is purged from the installation
and the resin bed is rinsed (it is normal for the rinse
water to show some discoloration!); close the tap.
7.
Check the water softener and all hydraulic connections
for leaks.
After the first regenerations of the water softener,
some slight discoloration of the treated water might occur.
This is totally harmless and will disappear rapidly!
BRINE CABINET
8.
Add water conditioner salt to the brine cabinet.
ELECTRONIC CONTROL PANEL
9.
Program the electronic controller.
ADJUSTMENT RESIDUAL HARDNESS
WITH FACTORY BYPASS (optional)
Picture 6
10.
Adjust the residual hardness of the water that leaves the
softener, by means of the adjusting screw, incorporated
in the ‘outlet’ valve of the factory bypass:
to raise the residual hardness: turn the screw
counter clockwise; usually 1 turn corresponds to a
residual hardness of ±4 °f (±2 °d), 2 turns to ±8 °f (±4
°d).
to reduce the residual hardness: turn the screw
clockwise.
PERFORM REGENERATION
11.
Manually initiate a regeneration, by pressing the
scroll
button repeatedly until the display shows:
12.
Leave the water softener in this position; the countdown
timer will countdown to 0 sec and start a regeneration.
Regen in 10 sec
Содержание Eco 17L
Страница 1: ...2013 Aquion Inc TM EN Slimline Rev2013 08 Technical Manual WATER SOFTENER...
Страница 12: ...HYDRAULIC FLOW DIAGRAMS ECO Page 12 SERVICE REFILL BRINE PREPARATION BRINE DRAW SLOW RINSE...
Страница 13: ...HYDRAULIC FLOW DIAGRAMS ECO Page 13 SERVICE REFILL BRINE PREPARATION BACKWASH BRINE DRAW SLOW RINSE FAST RINSE...
Страница 18: ...EXPLODED VIEW SLIMLINE 11L 14L Page 18...
Страница 20: ...EXPLODED VIEW SLIMLINE 17L 24L 30L Page 20...
Страница 22: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 22...
Страница 24: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 24...
Страница 27: ...Page 27...
Страница 30: ...Page 30...
Страница 31: ...Page 31...
Страница 33: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 1 2 3 a 3 b...
Страница 34: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 4 a 4 b 5 a 5 b r 6...
Страница 35: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 7 8 a r 8 b r 8 c...
Страница 36: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 9 a 9 b 9 c r 10...