background image

TROUBLESHOOTING 

 

 

 

Page 14 

PROBLEM 

CAUSE

 

SOLUTION

 

Hard (untreated) water 
to service

 

Open or defective bypass 

Close or replace bypass 

Water softener in regeneration 

Wait  until  regeneration  finishes  or  manually 
advance regeneration to end 

No salt in brine cabinet 

Add salt and initiate regeneration manually 

Salt bridging 

Break  salt  bridge(s)  and  initiate  regeneration 
manually 

Change in raw water hardness 

Measure  the  hardness  of  the  incoming  untreated 
water and adjust programming accordingly 

Water softener fails to start a regeneration 

Refer  to  problem  “Water  softener  fails  to  start  a 
regeneration”  

Control valve fails to draw brine 

Refer to problem “Valve fails to draw brine” 

Decreasing exchange capacity of resin 

Clean or replace resin bed 

Loss of resin 

Refer to problem “Loss of resin” 

Leak at riser tube 

Verify that riser tube is seated correctly and is not 
cracked     

Residual hardness in 
treated water

 

Bypass not completely closed  

Close bypass 

Water softener fails to 
start a regeneration 

Faulty electrical supply 

Verify electrical service (fuse, transformer,...) 

Defective flow meter 

Clean and/or replace flow meter 

Defective PCB 

Replace PCB 

Defective drain solenoid 

Replace drain solenoid 

Body stem assembly switches continuously 

Check operating pressure; must be higher than 1,4 
bar 

Water softener uses 
too much salt

 

Excessive water in brine cabinet  

Refer  to  problem  “Excessive  water  in  brine 
cabinet” 

System regenerates too frequently  

Verify program 

Excessive water in 
brine cabinet

 

Control valve fails to draw brine 

Refer  to  problem  “Control  valve  fails  to  draw 
brine” 

Improper refill time setting 

Verify  that  refill  time  corresponds  to  the  proper 
salt level and amount of resin 

Missing refill flow control 

Verify  that  refill  flow  control  is  installed  and 
properly sized 

Leak from control valve to brine cabinet 

Clean  or  replace  plunger  and  solenoid  diaphragm 
of refill solenoid 

Salt taste in treated 
water 

Excessive water in brine tank 

Refer to problem “Excessive water in brine tank”  

Injector undersized 

Verify injector selection 

Improper brine/slow rinse time setting 

Verify  that  brine/slow  rinse  time  corresponds  to 
the proper salt level and amount of resin 

Loss of water pressure

 

Mineral or iron build-up in resin tank 

Clean  resin  bed  and  control  valve;  increase 
regeneration frequency  

Plugged lower and/or upper distributor  

Verify that distributors are free of debris  

Crushed lower and/or upper distributor 

Replace distributor(s) 

Drain line from control 
valve flows 
continuously 

Water softener in regeneration 

Wait  until  regeneration  finishes  or  manually 
advance regeneration to end 

Drain solenoid stuck in open position 

Clean drain solenoid 

Defective PCB 

Replace PCB 

Drain line from brine 
cabinet overflow flows 
continuously 

Excessive water in brine cabinet 

Refer  to  problem  “Excessive  water  in  brine 
cabinet” 

Leak between control valve and pressure tank 

Verify  seal  between    control  valve  and  pressure 
tank 

Control valve fails to 
refill brine tank

 

Improper refill time setting 

Verify that refill time corresponds to salt level and 
amount of resin 

Plugged refill flow control 

Clean refill flow control 

Loss of resin

 

Lower and/or upper distributor damaged 

Replace distributor(s) 

Leak between riser tube and upper distributor 

Verify that riser tube is seated correctly and is not 
cracked     

 

 

Содержание Eco 17L

Страница 1: ...2013 Aquion Inc TM EN Slimline Rev2013 08 Technical Manual WATER SOFTENER...

Страница 2: ...ow diagrams Eco Page 12 Hydraulic flow diagrams Eco Page 13 Troubleshooting Page 14 Electrical wiring diagrams Page 16 Default parameter settings Page 17 Exploded view Slimline 11L 14L Page 18 Explode...

Страница 3: ...rtaken by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water softener make sure to che...

Страница 4: ...oiler house or freezing temperatures can occur the water softener cannot be exposed to outdoor elements such as direct sunlight or atmospheric precipitation do not install the water softener too close...

Страница 5: ...e application treated water 1 Install the 3 valve bypass system 2 Screw the connection kit with nuts onto the elbow connections of the water softener make sure to install the gasket seals Tighten the...

Страница 6: ...show some discoloration close the tap 7 Check the water softener and all hydraulic connections for leaks After the first regenerations of the water softener some slight discoloration of the treated wa...

Страница 7: ...the message In such case entering one of the programming levels can possibly solve the problem However if the problem persists professional service is required SERVICE MODE In service mode the display...

Страница 8: ...scroll button the display will show Press the up or down button to set the language 2 Press the scroll button again the display will show Press the up or down button to set the time of day 3 Press th...

Страница 9: ...aration Cycle 2 Cycle 2 Backwash Cycle 3 Brine draw slow rinse Cycle 3 Cycle 4 Fast rinse Cycle 5 7 Press the scroll button again the display will show Press the up or down button to set the type of w...

Страница 10: ...e calculated volume of softened water between regenerations Hardness display shows the setting of the water hardness Rsrv display shows the setting of the reserve capacity Regen display shows the sett...

Страница 11: ...rol valve and water conditioner salt The user should make sure that the brine cabinet is always kept full of water conditioner salt Therefore he should periodically check the salt level inside the bri...

Страница 12: ...HYDRAULIC FLOW DIAGRAMS ECO Page 12 SERVICE REFILL BRINE PREPARATION BRINE DRAW SLOW RINSE...

Страница 13: ...HYDRAULIC FLOW DIAGRAMS ECO Page 13 SERVICE REFILL BRINE PREPARATION BACKWASH BRINE DRAW SLOW RINSE FAST RINSE...

Страница 14: ...fails to draw brine Improper refill time setting Verify that refill time corresponds to the proper salt level and amount of resin Missing refill flow control Verify that refill flow control is instal...

Страница 15: ...or and or brine restrictor Clean injector and or brine restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line...

Страница 16: ...4VAC auxilliary contact closed during regeneration max 500mA refill solenoid white drain solenoid key pad ECO flow meter power lead 24VAC auxilliary contact closed during regeneration max 500mA refill...

Страница 17: ...56 5 1 f M3 L equals 2 9 d M3 L 2 When the Exchange capacity per liter resin is changed the refill cycle time needs to be adjusted accordingly Model Eco Resin 11 17 24 Hardness unit 1 f f f Exchange...

Страница 18: ...EXPLODED VIEW SLIMLINE 11L 14L Page 18...

Страница 19: ...rine well 47 cm 14 38536 Screw rivet brine well 15 H1016 4 Brine well cap bottom 16 72263 Twist lock clamp power cord 17 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 18 70971 Power cord 19 7276...

Страница 20: ...EXPLODED VIEW SLIMLINE 17L 24L 30L Page 20...

Страница 21: ...rine valve assembly 464 to be cut to length 13 BW3 5 088 Brine well 14 38536 Screw rivet brine well 15 H1016 4 Brine well cap bottom 16 28 298 11 Transformer 230 24V 50 Hz 24VA EuroT plug 17 72263 Twi...

Страница 22: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 22...

Страница 23: ...54 Spring clip 25 186 118 O ring brine plug 26 541 273 Brine plug 27 72467 Union gasket 2x 28 72542 Elbow inlet 29 19 19 Clip drain flow adjuster 30 186 134 O ring drain flow adjuster 2x 31 541 238 Dr...

Страница 24: ...EXPLODED VIEW VALVE BODY ASSEMBLY ECO Page 24...

Страница 25: ...1 254 Spring clip 25 186 118 O ring brine plug 26 541 273 Brine plug 27 72467 Union gasket 2x 28 72542 Elbow inlet 29 19 19 Clip drain flow adjuster 30 186 134 O ring drain flow adjuster 2x 31 541 238...

Страница 26: ...2 72216 Valve head 3 541 300 G Drain flow control 2 0 gpm Eco 11L Eco 15L Eco 20L 541 300 J Drain flow control 2 6 gpm Eco 26L 4 185 115 1 O ring drain line adaptor 5 74018 Nut drain solenoid 6 74016...

Страница 27: ...Page 27...

Страница 28: ...vice flow rate 1 bar pressure drop m hr 2 3 2 3 2 1 1 9 2 0 Recommended maximum service flow rate m hr 3 1 1 1 4 1 7 2 4 3 0 Rinse water usage per regeneration Ltr 4 61 64 101 107 131 2 Indicative num...

Страница 29: ...capacity per kg salt m x d 23 Service flow rate 1 bar pressure drop m hr 2 3 2 1 2 1 Recommended maximum service flow rate m hr 3 1 1 1 7 2 4 Rinse water usage per regeneration Ltr 4 110 139 175 2 Ind...

Страница 30: ...Page 30...

Страница 31: ...Page 31...

Страница 32: ...AQUION INC Lammerdries Oost 30c B 2250 Olen Belgium 32 0 14 28 51 71 32 0 14 28 51 70 RPR RPM Turnhout BWT TVA VAT BE 0882 738 206 infobelgium eriewatertreatment com www eriewatertreatment com...

Страница 33: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 1 2 3 a 3 b...

Страница 34: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 4 a 4 b 5 a 5 b r 6...

Страница 35: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 7 8 a r 8 b r 8 c...

Страница 36: ...2012 Aquion Inc PP SlimlineEco Rev2012 05 r 9 a 9 b 9 c r 10...

Отзывы: