8
6770
2
2021
-
PJC421 & PJC422
Control Panel - Alarms
MC_0407
Show list of active alarms.
Access alarm
list
Active alarm
All TP-35 that are turned on and connected to the S-Link bus enters alarm state if it receives an alarm code or if communication with associated
devices is lost. The alarm state is indicated by a blinking red background, an audible alarm signal, and the
Access alarm list
icon displayed in the lower-
left corner.
It is not possible to operate thrusters with active alarms. Exceptions are
Oil over temperature alarm
,
Low oil level
alarm
generated by PHC3, and
auxiliary power supply alarm
on DNV product variants.
Alarm list, audible alarm signal active
Push
Mute active alarms
on one TP-35 to mute the audible alarm signals on all Sleipner control panels that are turned on and connected to the S-Link
bus.
Unmuted alarms are listed in red, and muted alarms are listed in dark blue. Active alarms are not automatically cleared, even if the alarm state is no
longer present in the device. Active alarms must always be cleared by the user to be removed from the alarm list.
Red flashing background
Access alarm list
Mute audible alarm signal.
Clear all active alarms and mute audible alarm signals. A command to clear active alarms is sent to all devices connected to the
S-Link bus. If an alarm state is still present in a device, a new alarm will be triggered in TP-35, and the audible alarm signal will
be reactivated.
Red text indicates unmuted alarms
Blue text indicates muted alarms
Mute active alarms
Number of active alarms
Dark blue text indicates muted
alarms
Clear active alarms
Muted alarms
Return to dashboard view
Clear active alarms
Control Panel - Alarms
MC_0407
Alarm list, muted audible alarm signal
All active alarms are still listed after the audible alarm signal is muted.
Clear active alarms
have the same functionality as when the audible alarm signal is not muted.
Immediate Stop alarm
If the STOP button on TP-35 is pushed, a
STOP
message will be sent to all thrusters connected to the S-Link bus. An audible alarm signal will be given,
and a notice will be displayed on the screen. The thrusters will immediately stop after receiving the
STOP
message and then broadcast the
STOP
Activated message.
If the
STOP
Activated message is not received by TP-35 within 1 second after the
STOP
button is pushed, the
STOP
notice will be closed.
The
STOP
button must be pushed for 2 seconds to disable the stop function.
Pressing the
STOP
button with a hydraulic controller connected to the S-Link bus will activate the dump valve and all hydraulic consumers will be
disabled.
The
STOP
Activated message will be displayed on all Sleipner control panels that are turned on.
Return to the dashboard view
Clear all active alarms. A command is sent to all devices connected to the S-Link bus to clear active alarms. If the alarm state is
still present in a device, a new alarm will be triggered in TP-35 and the audible alarm signal will be reactivated.
Содержание PJC421
Страница 41: ...41 6770 2 2021 PJC421 PJC422 13 1 13 1 4 0 4x 127 6 96 1 83 0 78 9 110 4 114 5 95 5 127 7 TP 35 Top Mount...
Страница 43: ...43 6770 2 2021 PJC421 PJC422 6 5 94 5 112 4 74 0 74 0 10 4x 4x 3 PJC421 PVREL...
Страница 44: ...44 6770 2 2021 PJC421 PJC422 84 0 166 0 74 0 156 0 98 0 6 5 95 0 195 0 10 4x 6x 3 PJC422 PVREL...
Страница 45: ...45 6770 2 2021 PJC421 PJC422 4 x 5 5mm 17 25 79 0 78 5 44 0 74 0 PJC421 LF90 PJC422 LF90...
Страница 46: ...46 6770 2 2021 PJC421 PJC422 4x 5 5mm 70 0 79 2 79 2 39 6 39 6 PJC421 LE90 PJC422 LE90...
Страница 47: ...47 6770 2 2021 PJC421 PJC422 74 0 47 0 79 2 79 2 2 6 16 1 PJC421 LF90X PJC422 LF90X...
Страница 50: ...50 6770 2 2021 PJC421 PJC422 MC_0037 Notes...
Страница 51: ...51 6770 2 2021 PJC421 PJC422 MC_0037 Notes...