19
6770
2
2021
-
PJC421 & PJC422
Control Panel - Menu Navigation
MC_0407
Release command
When the control panel is IN COMMAND, Main Workstations and Remote Workstations can release command to allow for other workstations to take
command. When command is released, an audible signal will be given to indicate that the state of the control panel has changed from IN COMMAND to
NOT IN COMMAND. If command is released when thrusters are running, the thrusters will stop.
If a Remote Workstation request command when another Main or Remote Workstation is in command, a notice is displayed informing that another
workstation is in command. The notice disappears after 3 seconds, or it can be manually closed.
In such a situation, the other workstation must release the command before the command can be transferred.
Release command.
Closes the notice.
PHC-3
Fault Codes
MC_0117
Fault Code
Description
Cause
Action
10500.0.10
PHC Oil Level - Level Low
Hydraulic oil level is low
"-Limit use of thruster
-Inspect hydraulic oil level
-Check system for leaks and refi ll hydraulic oil"
10500.0.13
PHC Oil Level - Open Circuit
Analog oil level sensor open circuit
"-Sensor not connected or wire break.
-Verify sensor type in parameter 0201
-Disconnect sensor and measure that sensor resistance value is in
range 0-180ohm."
10501.0.11
PHC Oil Temp - Level High
Oil temperature higher than 75°C (167°F)
"-Limit use of thruster to prevent temperature to rise.
-Check if cooling pump is running and there is cooling water flow.
-Inspect seawater fi lter
-Verify that cooling pump is enabled in parameter 0301"
10501.0.13
PHC Oil Temp - Open Circuit
Analog oil temp sensor open circuit
"-Sensor not connected or wire break.
- Disconnect sensor and measure that sensor resistance value is in
range 104ohm-147Kohm
-Wrong sensor is defi ned in parameter 0201"
10501.0.16
PHC Oil Temp - Short Circuit
Analog oil temp input short circuit
"-Input shorted to GND, check wiring/sensor
-Disconnect sensor and measure that sensor resistance value is in
range 104ohm-147Kohm"
10502.0.13
PHC Stabilizer Pressure - Open Circuit
Stabilizer pressure sensor open circuit
"-Sensor not connected or wire break.
-System incorrectly confi gured with stabilizer, parameter 1001
-Replace sensor"
10502.0.16
PHC Stabilizer Pressure - Short Circuit
Stabilizer pressure sensor short circuit
"-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor"
10502.0.19
PHC Stablizier Pressure - Under Limit
Stabilizer pressure has dropped below 20bar.
"-Check accumulator charge pressure
-Check PTO pressure (if PTO powered)
-Check system for oil leaks
-Check generator power supply to the VFD (is VFD motor speed
maximum when pressure alarming low)"
10502.0.20
PHC Stablizier Pressure - Over Limit
"Stabilizer pressure is higher than:
parameter 1013 PTO OVER-PRESSURE FAULT LEVEL running
from PTO (FW V1.029 an older, set point + 30bar running
from PTO)
or set point + 15bar running from AC motor"
"-Check Parameter 1013 PTO OVER-PRESSURE FAULT LEVEL
-Check PTO pressure setting
-Check accumulator charge pressure
-Check unload valve operation"
10502.0.26
PHC Stablizier Pressure - VALUE MAX
Stabilizer pressure reached sensor max value.
"-Check that correct sensor is fi tted
-Check that sensor range parameter 1010 match the sensor
-Check PTO pressure setting"
10502.0.200
PHC Stablizier Pressure - Timeout
Stabilizer pressure has not reached 60% of set point parame-
ter 1003 after 30sec.
"-Check pump feed shutoff valve.
-Check PTO pressure (if PTO powered)
-Check system for oil leaks"
10503.0.13
PHC System Pressure - Open Circuit
System pressure sensor open circuit
"-Sensor not connected or wire break.
-Verify system pressure, parameter 0104"
10503.0.16
PHC System Pressure - Short Circuit
System pressure sensor short circuit
"-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor"
10504.0.13
PHC AI 1 - Open Circuit
Analog Input 1 (4-20mA) sensor open circuit
-Sensor not connected or wire break.
10504.0.16
PHC AI 1 - Short Circuit
Analog Input 1 (4-20mA) sensor short circuit
"-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor"
10505.0.13
PHC AI 2 - Open Circuit
Analog Input 2 (4-20mA) sensor open circuit
-Sensor not connected or wire break.
10505.0.16
PHC AI 2 - Short Circuit
Analog Input 2 (4-20mA) sensor short circuit
"-Wires shorted or sensor defective, check wiring/sensor
-Replace sensor"
10508.0.13
PHC DOUT AC PUMP UNLOAD - Open Circuit
AC Pump Unload valve open circuit
"-Check for open circuit, power consumption < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001"
10508.0.51
PHC DOUT AC PUMP UNLOAD - Current High
AC Pump Unload valve current higher than 4.0A
-Check wires and connections for short circuit
10509.0.13
PHC DOUT ACCUMULATOR DUMP - Open
Circuit
Accumulator Dump valve open circuit
"-Check for open circuit, power < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001"
10509.0.51
PHC DOUT ACCUMULATOR DUMP - Current
High
Accumulator Dump valve current higher than 4.0A
-Check wires and connections for short circuit
10510.0.13
PHC DOUT STABILIZER - Open Circuit
Stabilizer valve open circuit
"-Check for open circuit, power consumption < 5.0 Watt
-System incorrectly confi gured with stabilizer, parameter 1001"
10510.0.51
PHC DOUT STABILIZER - Current High
Stabilizer valve current higher than 4.0A
-Check wires and connections for short circuit
10511.0.13
PHC DOUT COOLING PUMP HYDRAULIC - Open
Circuit
Hydraulic Cooling Pump valve open circuit
"-Check for open circuit, power consumption < 5.0 Watt
-Wrong cooling pump confi gured, parameter 0301"
10511.0.51
PHC DOUT COOLING PUMP HYDRAULIC -
Current High
Hydraulic Cooling Pump valve current higher than 4.0A
-Check wires and connections for short circuit
10512.0.13
PHC DOUT LS DUMP - Open Circuit
LS-Dump valve open circuit
"-Check for open circuit, power consumption < 5.0 Watt
-System wrong confi gured with thrusters, parameter 2001 or
2101"
10512.0.51
PHC DOUT LS DUMP - Current High
LS-Dump valve current higher than 4.0A
-Check wires and connections for short circuit
10513.0.51
PHC DOUT PUMP #2 - Current High
Pump #2 valve current higher than 4.0A
-Check wires and connections for short circuit
10514.0.13
PHC DOUT 5 - Open Circuit
Digital Output 5 is confi gured as crossover and output is open
circuit
"-Check for open circuit, power consumption < 5.0 Watt
-Output confi gured wrong, parameter 0505"
10514.0.51
PHC DOUT 5 - Current High
Digital Output 5 current higher than 4.0A
-Check wires and connections for short circuit
10515.0.13
PHC DOUT 6 - Open Circuit
Digital Output 6 is confi gured as crossover and output is open
circuit
"-Check for open circuit, power consumption < 5.0 Watt
-Output confi gured wrong, parameter 0506"
Содержание PJC421
Страница 41: ...41 6770 2 2021 PJC421 PJC422 13 1 13 1 4 0 4x 127 6 96 1 83 0 78 9 110 4 114 5 95 5 127 7 TP 35 Top Mount...
Страница 43: ...43 6770 2 2021 PJC421 PJC422 6 5 94 5 112 4 74 0 74 0 10 4x 4x 3 PJC421 PVREL...
Страница 44: ...44 6770 2 2021 PJC421 PJC422 84 0 166 0 74 0 156 0 98 0 6 5 95 0 195 0 10 4x 6x 3 PJC422 PVREL...
Страница 45: ...45 6770 2 2021 PJC421 PJC422 4 x 5 5mm 17 25 79 0 78 5 44 0 74 0 PJC421 LF90 PJC422 LF90...
Страница 46: ...46 6770 2 2021 PJC421 PJC422 4x 5 5mm 70 0 79 2 79 2 39 6 39 6 PJC421 LE90 PJC422 LE90...
Страница 47: ...47 6770 2 2021 PJC421 PJC422 74 0 47 0 79 2 79 2 2 6 16 1 PJC421 LF90X PJC422 LF90X...
Страница 50: ...50 6770 2 2021 PJC421 PJC422 MC_0037 Notes...
Страница 51: ...51 6770 2 2021 PJC421 PJC422 MC_0037 Notes...