32
Technical manual
DOL 278AT
13.6 Testing
13.6.1 Lamp Indications
Cause
Flashing sequence
Outdoor temperature
compensation active:
Switches on in the relevant
side(s) (yellow)
Misplaced outside sensor:
Move the outside sensor away
from the sunlight.
Flashes in both sides (yellow)
Short-circuited or
disconnected outdoor
temperature sensor:
Flashes in both sides (yellow)
Short-circuited or
disconnected indoor
temperature sensor:
Flashes in the relevant side(s)
(red)
Emergency opening:
Switches on in the relevant
side(s) (red)
As long as the emergency
opening is active
Opens:
Switches on in the relevant
side(s) (green)
While motor is opening
Phase break/mains failure
115/230 V:
The relevant battery lamp is
flashing (green, yellow or red)
Both emergency opening lamps
switches on (red)
Battery status:
Green > 80%
Yellow = 80-20%
Red < 20%
Constant light. One of the
battery lamps
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 sec. - unending
0,1 sec. 3 sec.
0,1 sec./0,1 sec.
0,5 sec./0,5 sec.
2 – 180 sec.
2 sec. - unending
0,1 sec/ 1 sec.