26
Technical manual
DOL 278AT
13
Installation Guide
In order to ensure maximum safety in an emergency situation, DOL 278AT may not supply
other products than autorized by SKOV A/S with 24 V DC voltage.
If it does, any subsequent consequences will be at the owner’s own risk.
13.1 Installation of Battery in DOL 278AT
Battery module 4Ah for DOL 278AT medium
Tick and attach the supplied battery date label to the outside of
the DOL 278AT cabinet.
Place the battery on the shelf in the DOL 278AT cabinet and
secure it with the included cable tie as shown.
Battery module 7Ah for DOL 278AT large
Do NOT connect the battery yet.
See Figure 3 (
F
).
13.2 Installation of the TEST Mains Switch
The TEST mains switch is located next to DOL 278AT in order to prevent unintended operation.
DOL 278AT will register any power failure on its own mains supply. DOL 278AT must therefore be
supplied from the same phase the climate computer’s house 1 mains connection.
Содержание DOL 278A
Страница 2: ......
Страница 14: ...14 Teknisk manual DOL 278T 5 5 3 Eldiagram DOL 278AT large DOL 278 Klimacomputer...
Страница 30: ...30 Technical manual DOL 278T 13 5 3 Wiring Diagram DOL 278AT Large DOL 278 Klimacomputer...
Страница 46: ...46 Technisches Handbuch DOL 278T 21 5 3 Schaltplan DOL 278AT Large DOL 278 Klimacomputer...
Страница 54: ......
Страница 55: ......