Page 43 of 56
SKIPPER
Electronics AS
Edition: 2021-09-16
ESN100 Operation and Installation Manual
Chapter: ESN100 Screen functions
Button
Description
Page A (lo/hi)
The Transducer connected to transducer connector 1 (if this is a dual
frequency transducer it will show the low or high frequency)
Page B (lo/hi)
The Transducer connected to transducer connector 2 (if this is a dual
frequency transducer it will show the low or high frequency)
Digital Font size
Adjusts the size of the depth text on the left.
Small – 1m viewing distance
Medium – 3m viewing distance
Large – 5m viewing distance
Depth value
The reference point from which the depth is measured
(Surface/Transducer/Keel)
Info buttons
The information on the right can be made fixed or to disappear after a
time
Information 1-5
Select the information/parameters to be shown on each information.
Bottom bars
The information on the bottom can be made fixed or to disappear after a
time
Bottom bar 1-3
Select the parameter/ information to be shown on the bottom bar. (1 is
fixed to range)