Page 26 of 56
SKIPPER
Electronics AS
Edition: 2021-09-16
ESN100 Operation and Installation Manual
Chapter: System Setup
Alert title Alert
message
Message
Description
Alert types
selectable
default
Alert
ID
ALF
Alert
ID
ALR
Remote
Ack
Shallow
water
SHALLOW
WATER
DEPTH BELOW
KEEL <xx M
• ALF CatA
• ALF CatB
ALF CatA 3031
230
No
Yes
Deep
Water
DEEP
WATER
DEPTH BELOW
KEEL > XX M
• Caution
• Warning
• OFF
Caution
3033
3032
457
No
Yes
Lost
bottom
LOST
BOTTOM
NO DEPTH
DETECTED
• Caution
• Warning
• OFF
OFF
3009
3008
345
No
Yes
System
Error
SYSTEM
ERROR
SENSOR COM-
MUNICATIONS
or
DISPLAY COM-
MUNICATIONS
• Caution
• Warning
• Warning W-A
(Warning with
escalation to
alarm)
• OFF
Warning
3016
3015
3015-
3014
458
457
No
Yes
System
internal
failure
INTERNAL
ERROR
SETTING
DISRUPTING
SYSTEM
• Caution
• Warning
• OFF
OFF
3063
3062
459
No
Yes
Shallow water alarm : The Shallow water alarm is mandatory, but can be used in one of 2 methods
- CAT A ALF/ACN/ALC: The newer IEC62923 standard allowing the system. In this mode no
remote status operations are available the system cannot be remotely acknowledged. Remote
silencing is available
- CAT B ALF/ACN/ALC The system is connected to an approved INS, All remote functions are avail-
able
Alerts
All alerts are category B unless otherwise stated.
Responsibility can be transferred on all alarms and warn-
ings.
The system will only support 1 instance of each type of
alert at a time.
Aggregation is not supported.
The system can be locally or remotely silenced for a
period of 30 seconds. After this time the audible signal will
return. New alerts that occur during the silenced time will