Page 6 of 56
SKIPPER
Electronics AS
Edition: 2021-09-16
ESN100 Operation and Installation Manual
Chapter: Introduction and Specification
Introduction and Specification
The SKIPPER ESN100 is a navigational echo sounders. It is made to fulfill the ISO/IMO standards, as well as
the modern IEC standards for maritime equipment and alarm handling.
Features include:
•
Easy and logical operation via a touch display
•
Flexible installation with minimal wiring
•
Basic but comprehensive communication and features
The system has a single active channel, and can be used on both 50 or 200 kHz transducers. The system is
simple to install, and simple to use having automated functions such that the need for adjustment is minimal.
Specification:
Function
Value
Frequency (selectable)
50kHz and 200kHz
Two transducers can be connected at one time. Only one is
operational at a time.
Both transducers can be 50kHz and or 200kHz. If dual fre-
quency 50/200kHz transducer, an automatically switching
of frequency may be programmed (200kHz in shallow water
0-100m, 50kHz in deeper water >100m)
Electrical parameters
CU-M001-SB Control Unit
JB50E1-SA Transceiver unit
Nominal 24VDC ( Max 4W) 21VDC to 36VDC
24VDC (Max 8W) limits 21-36VDC
Connections
ESN100-SB Control unit
JB50E1-SA Transceiver unit
WAGO spring connector (12 pins)
1 port RJ45 (IEC61162-450)
1 x 2 pole connector 24VDC In( up to 1.5mm)
1 x 2 pole connector 24VDC Out to display( up to 1.5mm)
2x 3 pole connector for transducer (up to 1.5mm)
1x 2 pole connector for communication (up to 1.5mm)
1x 2 pole connector for power alarm (up to 1.5mm)
Acoustic output Power (Max)
600W
Outputs from control unit
1 x NMEA (IEC61162-1)
DPT,PSKPDPT, DBS,DBK,DBT, ALR, ALF
Inputs to control unit
2 NMEA (IEC61162-1)
Accepting signals from GPS, Gyro, Alarm, Draft, Dimming
Alarms
Follows IEC standards (ALF and ALR)
Functions
Auto Gain, TVG and Power
Transducer positioning
Internal sounder for alarm/button press
Depth logging
Basic 24 hours,
External logging feature over network.
Transducer type, frequency, expected
min/max depth range
ETN050, 50 kHz, 1m-450m
ETN200, 200kHz, 1m-250m
ETN200S, 200kHz, 1m-200m
ETS50200, 50kHz and 200kHz, 1m -450m