![Skipper ESN100 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/skipper/esn100/esn100_operation-and-installation-manual_1288612028.webp)
Page 28 of 56
SKIPPER
Electronics AS
Edition: 2021-09-16
ESN100 Operation and Installation Manual
Chapter: System Setup
Values and settings:
Shallow Water
(keel)
The user set value at which the alarm sounds as the vessel approaches
shallow water
Deep Water (keel) a second warning/caution triggered if the vessel goes deeper than the
specified value - Setting value to zero will deactivate them.
Settings
Alert Group
The system will communicate with a CAM using a group. The default of this
system is NAV, but this can be changed in the screen setup. THe communi-
cation with the alarm management can also be via a second group such as
CAM1 or BAM1. This can be selected here, and in that case the alarm mes-
sages will be sent to this group only.
BAM/CAM SFI
The Alarm management system will have a unique system function identity. This
can be entered here. Communication with this is normally point to point, and other
systems will not be able to send commands to this system
Alert type
This allows you to select the current alert method (ALF/ACNALC) or legacy (ALR/
ACK) The ID’s of the alerts will change to meet the demands of the standard
Escalation time
The amount of time a warning can remain unhandled, before resending, or
changing to alarm status..