background image

Page 32 of 56

SKIPPER

 Electronics AS

Edition: 2021-09-16

ESN100 Operation and Installation Manual

Chapter: PC connection

Printing Setup on PC

The printer will print a full page of information approximately every 15 minutes. The Printed page is in a 

.pdf format, and uses the local pdf driver of the PC. If the format is wrong, we recommend using the win-

dows PDF or adobe acrobat drivers. 

Both the PC connected to printer and the ESN100 has to be set up correctly to be able to print. 

Select the printer to be used.

Select a temporary file if you do not wish to use the default.

Press “Start printing”.

Follow the connection and process details on the Log screen.

Search for the ESN100 system to be con-

nected to.

Click on the “Show print / Logfile” button.

In SKIPPER service software 

Select ESN100 > Select the printer tab.

(Software download available from 

www.skipper.no)

Содержание ESN100

Страница 1: ...Document no DM G004 SB Rev 2123 For software rev from 1 1 0 Edition 2021 09 16 SKIPPER Electronics AS www skipper no ESN100 Operation and Installation Manual Single channel Dual frequency Echo sounder...

Страница 2: ...u versement de dommeges et int r ts Copying of this document and giving it to others and the use or communication of contents thereof are forbidden without express authority Offenders are liable to th...

Страница 3: ...20 Dimming setup 21 Alert setup 22 PC CONNECTION 31 Printing Setup on PC 32 Printing Setup on ESN100 33 Download recorded data 34 Software upgrade 34 ESN100 SCREEN FUNCTIONS 35 Selectable Information...

Страница 4: ...point of the vessel M Meters ft Feet ftm Fathoms m s Speed in meters second kHz kilohertz Frequency A Automatic mode system self adjusts range and gain ALF Alarm method according to IEC61924 MSC 302 w...

Страница 5: ...V Volts DC Direct Current for voltage CAM Central alarm management INS Integrated navigation system LAN Local area network SFI System function identifier from standard IEC61192 450 UDP Data sent on t...

Страница 6: ...itching of frequency may be programmed 200kHz in shallow water 0 100m 50kHz in deeper water 100m Electrical parameters CU M001 SB Control Unit JB50E1 SA Transceiver unit Nominal 24VDC Max 4W 21VDC to...

Страница 7: ...he transceiver An additional RJ45 connector can be used for LAN communication JB50E1 SA Transceiver unit This unit contains connections for 2 transducers of either 50 or 200kHz a con nection for a sin...

Страница 8: ...ound the transducer and be tear drop shaped Do not mount transducers close to the propeller or aft of other hull installations outlets vents or other protruding details It is necessary to select a par...

Страница 9: ...56 between display unit and transducer Normally this will be near the bridge area for easy supply of 24VDC supply If the transducer s are forward then there is an alternative to position the transduce...

Страница 10: ...O2768m Gen tolerance Eur projection Drwg no Name Edition date Sheet Revision Scale Designed by date Approved by date Electronics AS Wiring Diagram ESN100 SB to JB50E1 SA CD 2040 B 01 1 of 1 2020 08 27...

Страница 11: ...ansceiver unit JB50E1 SA requires 24VDC power supply Alternative 1 Display powered from JB50E1 SA In this configuration the system is switched on off by the power switch inside JB50E1 SA unit Power in...

Страница 12: ...complying with IEC62923 1 2 2018 and IEC62288 2014 ALR is the older standard and may comply with IEC61924 2 2012 and IEC62288 2014 only by connecting the Power failure alarm relay in JB50E1 SA to the...

Страница 13: ...l Chapter Introduction and Specification PC connection ESN100 can be connected via a LAN cable to a PC Features available via the ethernet LAN connector to a PC with SKIPPER software Printing Any prin...

Страница 14: ...parameters of the system or parameters being sent into the system from other equipment These parameters will after a short time slide off screen Touching the screen will make them return All these pa...

Страница 15: ...or combined 50 200 transducer fitted To select the correct fixture start the system and go to the config menus and then the ES setup Here you can select the Transducer menu and by clicking on the tra...

Страница 16: ...set for Max power and Max range These can be changed in the settings of Other See section Other Transducers At least 1 installed transducer should be within the SKIPPER approved list Non SKIPPER trans...

Страница 17: ...in the option codes tab This is to prevent users inadvertently changing parameters that can make the system perform poorly Screen Main setup Auto functions will take control of range gain and frequen...

Страница 18: ...is DPT output and ALARM outputs set to the ALF version of the standard NMEA style sentences will be shown as the 3 letter mnemonic when the sentence is sent or received The left side show a terminal...

Страница 19: ...ommended to be installed Time ZDA Also accept GGA GLL RMC All accepted NMEA inputs will be logged in history file Format Function __DDC X yy X C nn Dimming function X O N K D YY is the system will acc...

Страница 20: ...Screen setup Software version can be updated via Service software Serial number of this product Hardware and firmware version and serial number of the JB50E1 transceiver unit Only English currently av...

Страница 21: ...sages are sent on one of a number of multicast addresses ports as specified in the standard These are called transmission groups and the natural group for the system is navigation NAVD Messages are se...

Страница 22: ...ategory A alarm On a single channel ESN100 the shallow alarm will be triggered when the depth goes from deeper area passes the alarm limit on the active transducer If the system is part of an approved...

Страница 23: ...be more information about the cause Alerts will be logged in the 24h history and can be seen in the table view or on the history screen using the mark feature The alerts will be sent out using the IE...

Страница 24: ...Default Description Alert group DEFAULT CAM1 CAM2 BAM1 BAM2 Default The LWE group for alert messages to be sent on Default is the group set for the system in Screen setup Networks BAM CAM SFI XXYYYY...

Страница 25: ...on 2021 09 16 ESN100 Operation and Installation Manual Chapter System Setup Alarm sentences The serial sentences follow the latest standards ALF messages are in some cases accompanied by a second ALF...

Страница 26: ...nal failure INTERNAL ERROR SETTING DISRUPTING SYSTEM Caution Warning OFF OFF 3063 3062 459 No Yes Shallow water alarm The Shallow water alarm is mandatory but can be used in one of 2 methods CAT A ALF...

Страница 27: ...3022 460 Yes Unsynchro nised clock UNSYNCH CLOCK NO EXTER NAL CLOCK INPUT Caution Off Off 3119 119 No Extra comments A number of alerts will provide a second sentence with some diagnostic help stating...

Страница 28: ...ed in the screen setup THe communi cation with the alarm management can also be via a second group such as CAM1 or BAM1 This can be selected here and in that case the alarm mes sages will be sent to t...

Страница 29: ...No beep No symbol Rectified acknowledge Normal No beep No beep Silenced alarm No beep for 30 seconds No beep for 30 seconds Responsibility transferred No beep No beep Caution No beep No beep If respo...

Страница 30: ...of alerts The following shows the NMEA output for an alarm test of all alarms warnings cautions The Skipper service software contains a BAM simulator as part of the Communications terminal emulator ap...

Страница 31: ...o be preconfigured to be on the same subnet mask as the ESN100 e g 172 16 1 xxx The ESN100 default IP address is 172 16 1 105 Setting up static IP address in Windows 1 Click Start menu Control panel N...

Страница 32: ...commend using the win dows PDF or adobe acrobat drivers Both the PC connected to printer and the ESN100 has to be set up correctly to be able to print Select the printer to be used Select a temporary...

Страница 33: ...e printed Echogram with relevant information or and a table of marks giving time and depth when changes have been made to the system or alarms have been triggered When the printer is first set to ON o...

Страница 34: ...her to delete the files on the display giving more room Files available for download are History files in PDF format The PDF files are the same files as being printed The system has about 2 days of fi...

Страница 35: ...Hz in the bow and 200 kHz aft With this system it is also possible to install a dual frequency 50 200 kHz transducer both forward and aft and the system can be made to select the best frequency at any...

Страница 36: ...epth changes If the user decides to take control of one of the auto parameters the system will inform that it is taken out of Auto mode and the user then has full control The system can again be put i...

Страница 37: ...e right and below the screen Buttons on the information and bottom bar can be adjusted to show the information the user required in the run time setup Press and hold the button to see all the choices...

Страница 38: ...nged by pressing and holding TVG Time variable gain Predicts how much the sound will fades in the water and compensates Manual adjusting this will give stronger weaker signal near the surface and can...

Страница 39: ...is dimmed too far down press and hold the screen and it will return to a visible level The screen will not dim fully down if an alarm is active If an alarm becomes active when fully dimmed the screen...

Страница 40: ...Depth below keel The depth value from the lowest point of the hull Depth below transducer The depth value to the bottom from the face of the transducer Speed from GPS Speed over ground from a connecte...

Страница 41: ...short press on the information will move to the next natural value A long 3 second press will show a menu of the available options RANGE is always available in the bottom left position with a single...

Страница 42: ...100 Screen functions Changing the look of the screen Go to Runtime Menu by pressing config in the top left In this menu you will see the available Pages and these can be individually tailored to show...

Страница 43: ...ow or high frequency Digital Font size Adjusts the size of the depth text on the left Small 1m viewing distance Medium 3m viewing distance Large 5m viewing distance Depth value The reference point fro...

Страница 44: ...ESN100 is saving depth information for 24 hours data recorded every 1 minute This data can be shown on a single screen and is available in the HISTORY Menu By selecting table the depth of at least ev...

Страница 45: ...Page 45 of 56 SKIPPER Electronics AS Edition 2021 09 16 ESN100 Operation and Installation Manual Chapter ESN100 Screen functions By changing the range you can see more detail of the echogram...

Страница 46: ...ving depth or run a simulation from file Depth The value to be sent or the value the moving depth will move above and below Test alarm Send all known alarms to the output These can be acknowledged sil...

Страница 47: ...the SNR calibration can be performed and the system will optimise itself Each ping is plotted in the Scope screen Transceiver unit JB50E1 SA Diagnostics There are 5 LEDs on the PCB giving the status...

Страница 48: ...TS50200 and Furuno 8B 200B These updates can be downloaded from the skip per website when the ETT software is started Connecting the ETT985 to the transducer ports of the JB50E1 SA unit and then runni...

Страница 49: ...16 ESN100 Operation and Installation Manual Chapter Diagnostics Display mounting option The display is designed for flushmount installation with an option to purchase a wallmount desk top bracket Par...

Страница 50: ...hield to connector or Gland Shield Gland Output DPT ALARM Input ZDA ALARM Position Speed Dimming Draft 24VDC Shield Shield A B Display can be powered directly or via JB50E1 unit Note 1 Cable spec see...

Страница 51: ...x 1 Installation drawings 242 158 125 140 17 34 5 4 3 6 5 125 224 224 3 32 3 37 148 2 140 4 1 155 155 32 3 37 CUT OUT C 2 3 1 4 B A D E F Approved by date ST 2017 11 16 Designed by date Outline drawin...

Страница 52: ...Page 52 of 56 SKIPPER Electronics AS Edition 2021 09 16 ESN100 Operation and Installation Manual Chapter Appendix 1 Installation drawings JB50E1 SA Transceiver unit outline drawings...

Страница 53: ...elector The ESN100 has two transducer terminals selectable from software A transducer selector switch can be installed if more than two transducers are required The transducer selector switch will onl...

Страница 54: ...797 Form A 2x Stud M4 x 12 Drilling holes 4 5 0 177 ENS518 TRANSDUCER SELECTOR FORE AFT RAL 9005 RAL 9005 RAL 9005 ZOA 01171 Nitril O Ring 110 X 2 50mm ZOA 01172 x4 Lock nut M4 DIN985 A4 ZOA 01172 x4...

Страница 55: ...Page 55 of 56 SKIPPER Electronics AS Edition 2021 09 16 ESN100 Operation and Installation Manual Chapter Appendix 1 Installation drawings This page is intentionally left blank...

Страница 56: ...SKIPPER Electronics AS Telephone 47 23 30 22 70 Enebakkveien 150 www skipper no P O Box 151 Manglerud E mail support skipper no 0612 Oslo Norway Co reg no NO 965378847 MVA...

Отзывы: