EN
11. Troubleshooting
11
10
- 65 -
951-171-021
Version 02
11.
Troubleshooting
Fault table 1
Fault
Possible cause
Remedy
Pump does not run
Power supply to pump interrupted
Check whether one of the indicated faults is present and rem-
edy it in the frame of responsibilities.
Faults outside of your own responsibility have to be reported to
your superior to initiate further measures.
If the fault cannot be determined and remedied, please contact
our Customer Service.
- Superior machine is switched off
- Connection cable of pump is loose or defective
- External fuse is defective
Pump is in the pause time mode
Pump motor is defective
Pump control PCB or power supply board is defective
Internal cable break
Pump runs
but supplies no or only
little lubricant
Blockade, fault within the centralized lubrication system
Defective check valve
Defective pressure relief valve
Suction bore of pump element is clogged
Close pump element
Air pockets in the lubricant/ under the follower plate
Too high lubricant consistency
(at low temperatures)
Too low lubricant consistency
(at high temperatures)
Wrong configuration of metering device within the centralized
lubrication system
Check whether one of the indicated faults is present and rem-
edy it in the frame of responsibilities.
Faults outside of your own responsibility have to be reported to
your superior to initiate further measures.
If the fault cannot be determined and remedied, please contact
our Customer Service.