Factor
Effect
High horsepower motors at
Low Operating Voltage
The characteristics of these motors are such that the
winding impedance is low, requiring high tester output
energy to surge test the windings. If the tester output is
insufficient to test a motor, then a power pack option may
be necessary, OR, if testing at the motor or the MCC, very
short feeder cables lengths will be needed.
Motor assembled with rotor
in place
The presence of the rotor will load the tester by drawing
energy from the tester like the secondary of a transformer.
Software fault messages
Non-VFD issues, causes, and actions with autophasing feature turned on.
Status
Failure type
Why failed message
PASS
No failure was detected according to the Test
Model given.
FAIL
USER ABORT
A User abort has been detected.
FAIL
EMERGENCY
SHUTOFF
Emergency Shutoff has been detected
Tested
Tester
No message, cannot determine Pass/Fail
because no test criteria was turned on.
FAIL
CANCEL
User cancelled test.
Resistance failure types
Non-VFD issues, causes, and actions with autophasing feature turned on.
Status
Failure type
Why failed message
FAIL
DELTA R
Resistance test result: Fail – DELTA R. Delta R
percent is out of tolerance.
FAIL
OPEN LEADS
Test results: Fail-OPEN LEADS. Open Leads
Detected.
FAIL
TOLERANCE
Test Results: Fail-TOLERANCE Resistance(s)
outside of user defined targeted range.
CAUTION
Reistance out of
range
Resistance values must be greater than 0.500
ohms for HIGH VOLTAGE LEADS and greater
than 0.001 for the RES LEADS. You may stop
Testing, reconfigure Test ID with the appropriate
leads, and repeat the test OR continue with the
remaining tests.
CAUTION
MAX R Range
Exceeded
Test Results: Caution – MAX Resistance Range
Exceeded.
Possible Open lead(s).
150
SKF Static Motor Analyzer—Baker AWA-IV User Manual
Typical winding faults
Содержание AWAIV-12
Страница 1: ...SKF Static Motor Analyzer Baker AWA IV User manual ...
Страница 2: ......
Страница 14: ...xii SKF Static Motor Analyzer Baker AWA IV User Manual Table of Contents ...
Страница 16: ...2 SKF Static Motor Analyzer Baker AWA IV User Manual About this manual ...
Страница 28: ...14 SKF Static Motor Analyzer Baker AWA IV User Manual Baker AWA IV Instrument Overview ...
Страница 88: ...74 SKF Static Motor Analyzer Baker AWA IV User Manual Database management and maintenance ...
Страница 90: ...76 SKF Static Motor Analyzer Baker AWA IV User Manual Set up of the Baker AWA IV analyzer ...
Страница 91: ...SKF Static Motor Analyzer Baker AWA IV User Manual 77 Set up of the Baker AWA IV analyzer ...
Страница 92: ...78 SKF Static Motor Analyzer Baker AWA IV User Manual Set up of the Baker AWA IV analyzer ...
Страница 124: ...110 SKF Static Motor Analyzer Baker AWA IV User Manual Special features of the Baker AWA IV ...
Страница 166: ...152 SKF Static Motor Analyzer Baker AWA IV User Manual Typical winding faults ...
Страница 180: ...166 SKF Static Motor Analyzer Baker AWA IV User Manual ...
Страница 181: ...SKF Static Motor Analyzer Baker AWA IV User Manual 167 ...
Страница 182: ...168 SKF Static Motor Analyzer Baker AWA IV User Manual ...
Страница 194: ...180 SKF Static Motor Analyzer Baker AWA IV User Manual Using the Baker ZTX with Baker AWA IV analyzers ...
Страница 210: ...196 SKF Static Motor Analyzer Baker AWA IV User Manual ...
Страница 234: ...220 SKF Static Motor Analyzer Baker AWA IV User Manual ...
Страница 240: ...226 SKF Static Motor Analyzer Baker AWA IV User Manual Glossary ...
Страница 248: ...234 SKF Static Motor Analyzer Baker AWA IV User Manual Index ...
Страница 249: ......