35
WARNING
TIMER
As a result of the new EU65 “Energy label” and
EU66 “Ecodesign” regulations issued by the
European Commission, which came into force as
from January 1st, 2015, our products have been
adapter to comply with these new requirements.
All of the models complying with the energy label
requirements, are equipped with new electronics
including a timer device for suction speeds control,
when the air capacity exceeds 650m
3
/h. Internal
motor models, with maximum air capacity higher
thank 650m
3
/h, are equipped with a timer device
that automatically switched the suction speed
from 4th to 3rd speed, after 6 minutes operation.
External motor models are equipped with remote
motos that, as for internal motor versions, include a
timer device that switches down the suction speed
when it exceeds 650m
3
/h. (See External Motors
intructions). Remote motors, whose air capacity
exceeds 650m
3
/h at both the 4th and 3rd speeds,
will have the following by default timer control
functions: The suction speed, after 6 minutes
of operation. If the appliance is working at 3rd
speed, it is automatically switched to 2nd speed,
after 7 minutes operation. Operation speeds can
also be changed during operation. The energy
consumption of the appliance in standby mode is
lower than 0.5W.
OTHER FUNCTIONS
Automatic turn off:
After 4 hours of continuous working from the
last setup, the appliance turns off and closes
austomatically.
Grease filters saturation:
After 30 hours of working, the speed indicators “D”
will all flash simultaneously signalling the grease
filters saturation.
To reset this alarm, hold down the “TIMER” button
for at least 3 seconds, while the carriage is open.
Calibration:
The rangehood carries out its self calibration every
3 complete cycles of its extractable unit.
By pushing the “TIMER” key 6 times consecutively
(MAX break between one push and the other is 3
seconds) all the LEDs will flash and tge calibration
will be reset.
After the next 3 cycles the downdraft the will carry
out its self-calibration.
Stand-by:
When the extractable unit is closed and the light
is switched off, the control panel, after 6 seconds,
activates the Stand-by function, reducing the
brightness of the LEDs. This function can be
stopped by pressing ON/OFF or LIGHT key.
Security system:
If there is an obstacle while the extractable unit is
closing, the Downdraft stops closing and and rises
again thanks to a security system.
This operation has to be carried out