SIQENS Ecoport 800
Operation
Page 29 of 48
Choose the desired mode and
confirm your selection:
▪
Only manually
▪
Battery voltage
▪
External input
5.1.1.
Battery voltage
In battery voltage operation, the Ecoport starts automatically as soon as the battery reaches a
preset voltage threshold.
The battery is then charged until a specified upper voltage threshold is reached.
The following values are predefined in the control panel for the end-of-charge voltage of different
battery types. You can manually assign other values via the control panel.
Battery type
Charging end voltage
24 V
48 V
Lithium battery
29.0 V
58.0 V
Lead-acid battery
28.8 V
57.6 V
Lead-AGM battery
29.4 V
58.8 V
Lead-gel battery
29.0 V
58.0 V
Custom
up to 30.0 V
Up to 60.0 V
Please note that voltages may vary depending on the cell type and manufacturer. Follow the
manufacturer's charging recommendations or contact SIQENS technical support.
Select: Battery voltage
Select “Battery voltage” in the
“Startup” menu.