SIQENS Ecoport 800
Installation
Page 24 of 48
Voltage thresholds
The following values are predefined in the control panel for the end-of-charge voltage of different
battery types. You can manually assign other values via the control panel.
Battery type
Charging end voltage
24 V
48 V
Lithium battery
29.0 V
58.0 V
Lead-acid battery
28.8 V
57.6 V
Lead-AGM battery
29.4 V
58.8 V
Lead-gel battery
29.0 V
58.0 V
Custom
up to 30.0 V
Up to 60.0 V
Please note that voltages may vary depending on the cell type and manufacturer. Follow the
manufacturer's charging recommendations or contact SIQENS technical support.
NOTICE
Defective batteries or a reduction in battery capacity due to aging effects or
improper use (e.g. deep discharge) can lead to an increased number of starts and
thus a shortened operating life of the Ecoport.
The Ecoport does not perform trickle charging of batteries. Regular full charging
via photovoltaics or an external battery charger can increase the lifetime of lead
batteries.