Refueling
Refueling of the Ecoport 800 is easy and safe thanks to the built-in dispensing head. A tank change
is also possible during operation. To prevent air from being drawn into the system via the suction
hose, the tank should be changed quickly (within 30 seconds).
NOTICE
The methanol is extracted evenly from the cartridges. Any difference regarding the
filling level in the cartridges is automatically balanced out. Please note that all tanks
should be placed on even ground.
Make sure that no air is sucked into the system through any of the hoses (for
example, through an empty or unconnected tank or cartridge).
1.
Remove dispensing head
Remove the dispensing head of the Ecoport or
the multi tank connector from the connected
cartridge by turning it counterclockwise.
2.
Open the cartridge / tank
Open the cap of the full cartridge using the barrel
wrench (this is included in the accessories of your
Ecoport) by turning it counterclockwise