SIQENS Ecoport 800
Installation
Page 21 of 48
SIQENS multi tank connector
The SIQENS multi tank connector enables the connection of several tanks or canisters with one
Ecoport.
Connectors multi tank connector
1
Connector to the SIQENS Ecoport
2
Dispensing head to be connected to cartridge or tank
NOTICE
The methanol is extracted evenly from the cartridges. Any difference regarding the
filling level in the cartridges is automatically balanced out. Please note that all tanks
should be placed on even ground.
Make sure that no air is sucked into the system through any of the hoses (for
example, through an empty or unconnected tank or cartridge).
2
1
▪
Connect the dispensing head of the
Ecoport to the connector socket
▪
Connect the dispensing heads of
the multi tank connector to the
individual tanks or cartridges.
▪
Make sure that all dispensing
heads are tightly and firmly
connected to the tanks or
cartridges.