SIQENS Ecoport 800
Service and maintenance
Page 43 of 48
ID
Error code
Description
1. Solution
2. Solution
42
E_CURRENT_ERROR
Faulty voltage
measurement
Please check the
battery cable for
firm hold
Please contact the
SIQENS support
48
E_MAX_SYSTEM_RESTA
RTS
Operating error
Please check the
battery and the fuel
tank for firm hold
and make sure that
supply and exhaust
air are free from
blockages
Please contact the
SIQENS support
50
E_ME_EMPTY_STARTU
P
The level of the media
unit is too low
Please contact the
SIQENS support
51
E_SB_TOO_HOT
The startup burner
temperature is too high
Please check the
ambient
temperature, as
well as the air
supply and exhaust
for any blockages
Please contact the
SIQENS support
58
E_SB_FLAME_GUARD
Defective startup
burner
Please contact the
SIQENS support
61
E_F5SY_CRITICAL_PERF
ORMANCE
Faulty sensor value or
defective fan
Please contact the
SIQENS support
62
E_SBG_CRITICAL_PERF
ORMANCE
Faulty sensor value or
defective fan
Please contact the
SIQENS support
63
E_F1L_CRITICAL_PERFO
RMANCE
Faulty sensor value or
defective fan
Please contact the
SIQENS support