![Sino Wealth SH61F83 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/sino-wealth/sh61f83/sh61f83_manual_1283060036.webp)
SH61F83
36
00C9H
TCCON
Initial Value
Time Capture Control Register
Bit[7:6]
-
00b
-
Reserved
Bit5
TC_CLREN
0b
R/W
Enable force clear TCAP0 free-run counter control bit
0: TCAP0 free-run counter is continued.
1: Enable force clear TCAP0 free-run counter function.
When force clear function enable, TCAP0 free-run counter is clear when a
rising or falling edge is detected on TC0 pad.
Reset Source: Hardware reset or USB reset
Bit4
TC_OVLEN
0b
R/W
Enable TC0_OVL event function
0: Disable TC0_OVL event.
1: Enable TC0_OVL event.
User can set both TC_CLREN and TC_OVLEN to detect the over-run event
of TCAP0 free-run counter.
Reset Source: Hardware reset or USB reset
Bit[3:2]
-
00b
-
Reserved
Bit1
TC0F_INT
0b
R/W
Enable Time Capture 0 falling-edge interrupt request.
When ETC0 = 1 & TC0F_INT = 1, the falling-edge on TC0 pad will cause an
ETC0 IRQ.
Reset Source: Hardware reset or USB reset
Bit0
TC0R_INT
0b
R/W
Enable Time Capture 0 rising-edge interrupt request.
When ETC0 = 1 & TC0R_INT = 1, the rising-edge on TC0 pad will cause an
ETC0 IRQ.
Reset Source: Hardware reset or USB reset
00CAH TCSCALE Initial Value
Time Capture Input Clock Scale Register
Bit[7:4]
-
0000b
-
Reserved
Bit3
-
0b
-
Reserved
Bit[2:0] TC0TS[2:0]
000b
R/W
Time Capture 0 free-run timer scale control:
000: Select 2us time scale for TCAP0 free-run counter base timer
001: Select 4us time scale for TCAP0 free-run counter base timer
010: Select 6us time scale for TCAP0 free-run counter base timer
011: Select 8us time scale for TCAP0 free-run counter base timer
100: Select 10us time scale for TCAP0 free-run counter base timer
101: Select 12us time scale for TCAP0 free-run counter base timer
110: Select 14us time scale for TCAP0 free-run counter base timer
111: Select 16us time scale for TCAP0 free-run counter base timer
Reset Source: Hardware reset or USB reset