SineDigital,Inc.
Installation Guide for MW-1500AP(H)
Entire contents 2003
SineDigital,Inc
.
All rights reserved
Page 25
(19) tftp
tftp <tftp server IP> <binary file name>
: Use this command to upgrade the MW-1500AP(H)'s
firmware by using TFTP to download the new firmware from the specified TFTP server.
AccessPoint> tftp
tftp> help
+------------------------------------------------
| Command | Description
+------------------------------------------------
| connect | connect to remote tftp
| get | receive file
| bye | exit tftp
| help | print help information
+------------------------------------------------
tftp> connect 172.16.0.80
connected to : 172.16.0.80
tftp> get mw1500h_app_630a_ge.bin app.2
getting from 172.16.0.80 : mw1500h_app_630a_ge.bin to app.2 [octet].
+--------------------------------------------------------------+
| Firmware header description.
| Image description : MMC MW-1500AP(H) Application 6.3.0
| Image size(comp) : 910992 bytes
| Image receive size : 911132 bytes
| Image Header checksum : 0x7062aac0
| Image total checksum : 0x41a26bc3
+--------------------------------------------------------------+
| Firmware upgrade procedure.
| Image confirmation OK !
| Image header checksum OK !!
| Image total checksum OK !!!
| Firmware type check OK(Ignored) !!!!
| File Type = 3 flash start = 0xbfc00000 offset =0x90000 flash length = 0x160000
| Flash area erase, writing ...... OK !!!!!
| Download buffer clearing OK !!!!!!
+--------------------------------------------------------------+
Firmware upgrade procedure complete.
tftp> bye
AccessPoint>
(20) write config
In order to save new settings or firmware upgrades into the MW-1500AP(H)'s memory, you
must type the command
write config
at the prompt after such actions.
Although the new configuration values have been saved into the MW-1500AP(H)'s memory
with the
write config
command, they will not become effective until after you reboot the MW-
1500AP(H). To reboot the MW-1500AP(H), type the command
reboot
at the prompt.