EN
11/28
FIRST POWER UP
6
Eclairage de zone
Charge max 200W
(2x100W)
5.3 Flashing light wiring
Description
Reference
Orange flashing light
9019453
Wiring in 24 Vdc
Connections
B4 : 32
B5 : 37
B5 : 38
J2:1
B4 : 31
J2:2
Configure the High power output 2 :
Flashing output J2 = 04
5.4 Lighting wiring
Configure the high power output 1 :
• Flashing output, J1 = 04
• J4=02 (expert mode needed : see
chapter 4 p.18)
If a flashing light is also connected
place its switch on « FLASH »
200W maximum
(2x100W)
When all wirings are done, replace the protective cover before powering on.
6.1 Display
The 2 digits on the left
display the current phase :
The 2 digits on the right display :
-The default if there is one
-The door position in other case
OPERATING PHASE DISPLAY
Waiting for a command
AC
Total internal opening
(complete opening phase with priority to inside panel)
OU
Total external opening
(complete opening phase with priority to outside panel)
OE
Closing (Closing phase in progress)
FE
Waiting to close
(Door open, on standby for closing)
AF
Reopening after safety close detection
LO
Reclosing after safety open detection
LF
DOOR POSITION DISPLAY
Door is opened
Door is neither opened or closed
Door is closed
Содержание SIMUDRIVE SD510